EATON - MOELLER PLN6-B6/1N-MW PLN6-B6/1N-MW 263161 EATON ELECTRIC Over current switch, 6A, 1Np, B-Char, AC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PLN6-B6/1N-MW 263161 EATON ELECTRIC Over current switch, 6A, 1Np, B-Char, AC

PLN6-B6/1N-MW

263161

EATON - MOELLER

12 Pcs.

Over current switch, 6A, 1Np, B-Char, AC Miniature circuit breaker (MCB), PLN6, 1-pole+N, tripping characteristic: B, rated current In: 6 A, rated switching capacity according to IEC/EN 60898-1: 6 kA, Switchgear for residential and commercial applications

Automation > Miniature circuit breaker (MCB)
Modular Switchgear - Tertiary

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An Eaton Moeller PLN6-B6/1N-MW Over current switch provides essential safety isolation in electrical distribution boards by reacting quickly to overcurrent conditions. It is a standard protective component for commercial and residential electrical installations.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Built-in depth (EF000218): 70.5 mm
  • Release characteristic (EF000889): B
  • Number of poles (total) (EF008618): 2
  • Number of protected poles (EF005548): 1
  • Rated current (EF000227): 6 A
  • Rated voltage (EF000228): 230 V
  • Rated insulation voltage Ui (EF001366): 440 V
  • Rated impulse withstand voltage Uimp (EF011980): 4 kV
  • Voltage type (EF000187): AC
  • Frequency (EF000416): 50 Hz
  • Power loss (EF005387): 1.9 W
  • Current limiting class (EF002568): 3
  • Flush-mounted installation (EF007517): No
  • Concurrently switching neutral conductor (EF005997): Yes
  • Over voltage category (EF002569): 3
  • Pollution degree (EF002570): 2

More info

▲
Miniature circuit breaker (MCB), 6A, 1Np, B-Char, AC
Miniature circuit breaker (MCB) PLN6, 1 pole+N, Tripping characteristic: B, Rated current In: 6 A, Rated switching capacity according to IEC/EN 60898-1: 6 kA, Switchgear for residential and commercial applications
[

Delivery program

Basic function
Miniature circuit-breakers
Number of poles
1 pole+N
Tripping characteristic
B
Application
Switchgear for residential and commercial applications
Rated current [In]
6 A
Rated switching capacity according to IEC/EN 60898-1 [Icn]
6 kA
Product range
PLN6
,

Technical data

Electrical
Rated switching capacity according to IEC/EN 60898-1 [Icn]
6 kA
,

Design verification as per IEC/EN 61439

Rated operational current for specified heat dissipation [In]
6 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
1.7 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+55 °C
linear, per +1 °C, results in a 0.5% reduction of current carrying capacity
,

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Miniature circuit breaker (MCB) (EC000042)
Electric engineering, automation, process control engineering / Electrical installation, device / Miniature circuit breaker system (MCB) / Miniature circuit breaker (MCB) ([email protected] [AAB905014])
Release characteristic
B
Number of poles (total)
2
Number of protected poles
1
Rated current
6 A
Rated voltage
230 V
Rated insulation voltage Ui
440 V
Rated impulse withstand voltage Uimp
4 kV
Rated short-circuit breaking capacity Icn EN 60898 at 230 V
6 kA
Rated short-circuit breaking capacity Icn EN 60898 at 400 V
6 kA
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V
0 kA
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V
0 kA
Voltage type
AC
Frequency
50 - 60 Hz
Current limiting class
3
Suitable for flush-mounted installation
No
Concurrently switching N-neutral
Yes
Over voltage category
3
Pollution degree
2
Additional equipment possible
Yes
Width in number of modular spacings
1
Built-in depth
70.5 mm
Degree of protection (IP)
IP20
Ambient temperature during operating
-25 - 55 °C
Connectable conductor cross section multi-wired
1 - 25 mm²
Connectable conductor cross section solid-core
1 - 25 mm²
]

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.