004280 EATON ELECTRIC On-Off switch, 9-pole + 2 N/O + 1 N/C, 32 A, 90 °, flush mounting
004280
004280
EATON - MOELLER
1 Pcs.
Connectors > Switch disconnector
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
004280 EATON ELECTRIC On-Off switch, 9-pole + 2 N/O + 1 N/C, 32 A, 90 °, flush mounting acts as a specialized multi-pole rotary switch utilized for intricate switching tasks in industrial control systems. Engineers typically integrate this flush-mounted component into custom control panels for multi-circuit management. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- 400 V: P
- Uninterruptible current rating: I or
- Rated Supported Pulse Voltage: U imp
- Rated Operating Voltage: U and
- Uninterruptible current rating: I or
- Rated Short-Duration Current Assigned (1 s current): I Cw
- Conditional Rated Short-Circuit Current: Iq
- Life expectancy, mechanics: The operations of
- Maximum Operating Frequency: Operations/h
- Rating, Motor Load Switch: P
- 220 V 230 V: P
- 230 V Star-delta: P
- 400 V 415 V: P
- 400 V Star-delta: P
- 500 V: P
- 500 V Star-delta: P
More info
▲Product range | On-Off switch | ||
Part of the reference group | S3 | ||
| with black, thumb and faceplate | |||
Number of poles | 9-Pole | ||
Auxiliary Contacts | |||
| N/S | 2 | ||
| N/A | 1 | ||
Degree of Protection | IP65 Front | ||
design | Flush mounting | ||
Contact sequence | |||
Manoeuvring angle | ° | 90 | |
Switching performance | Keeps | ||
Faceplate no. | |||
Faceplate | 0-1 | ||
Motor Power AC-23A, 50 - 60 Hz | |||
400 V | P | Kw | 15 |
Uninterruptible current rating | Ior | One | 32 |
Contact number of the units of | Contact Unit(s) | 6 |
| General | |||
Standards | IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL Switch-disconnector according to IEC/EN 60947-3 | ||
Climatic correction | Moist, Constant Heat, IEC 60068-2-78 Moist, cyclic heat, IEC 60068-2-30 | ||
Ambient Temperature | |||
Open | °C | -25 - +50 | |
Closed | °C | -25 - +40 | |
Overvoltage category/degree of contamination | III/3 | ||
Rated Supported Pulse Voltage | Uimp | V AC | 6000 |
Shock resistance mechanics | g | 15 | |
Mounting position | As required | ||
Protection against direct contact when operated from the front (EN 50274) | Finger and back of hand proof | ||
| Contacts | |||
Variable mechanics | |||
Number of poles | 9-Pole | ||
Auxiliary Contacts | |||
| N/S | 2 | ||
| N/A | 1 | ||
Electrical characteristics | |||
Rated Operating Voltage | Uand | V AC | 690 |
Uninterruptible current rating | Ior | One | 32 |
Note on the rated uninterruptible current !or | Uninterruptible current rating Iu is specified for max. the cross-section. | ||
Intermittent load capacity, class 12 | |||
AB 25 % DF | x Iand | 2 | |
AB 40 % DF | x Iand | 1.6 | |
AB 60 % DF | x Iand | 1.3 | |
Short Circuit Rating | |||
Fuse | One gG/gL | 35 | |
Rated Short-Duration Current Assigned (1 s current) | ICw | OneRms | 650 |
Note on the current short-term nominal assigned lcw | Current for 1 second | ||
Conditional Rated Short-Circuit Current | Iq | Ka | 1 |
| Switching capacity | |||
Nah, no way | One | 320 | |
Nah, no way | One | ||
230 V | One | 260 | |
400/415 V | One | 260 | |
500 V | One | 240 | |
690 V | One | 170 | |
Safety insulation according to EN 61140 | |||
among contacts | V AC | 440 | |
Current contact heat loss in the Iand | W | 1.1 | |
Current of the heat loss by auxiliary circuit in the Iand(AC-15/230 V) | CO | 1.1 | |
Life expectancy, mechanics | The operations of | x 106 | > 0.5 |
Maximum Operating Frequency | Operations/h | 1200 | |
AC | |||
AC-3 | |||
Rating, Motor Load Switch | P | Kw | |
220 V 230 V | P | Kw | 5.5 |
230 V Star-delta | P | Kw | 7.5 |
400 V 415 V | P | Kw | 11 |
400 V Star-delta | P | Kw | 15 |
500 V | P | Kw | 15 |
500 V Star-delta | P | Kw | 18.5 |
690 V | P | Kw | 11 |
690 V Star-delta | P | Kw | 22 |
Rated Operating Current of Motor Load Switch | |||
230 V | Iand | One | 23.7 |
230 V star-delta | Iand | One | 32 |
400 V 415 V | Iand | One | 23.7 |
400 V star-delta | Iand | One | 32 |
500 V | Iand | One | 23.7 |
500 V star-delta | Iand | One | 32 |
690 V | Iand | One | 14.7 |
690 V star-delta | Iand | One | 25.5 |
AC-21A | |||
Rated Switch Operating Current | |||
440 V | Iand | One | 32 |
AC-23A | |||
Motor Power AC-23A, 50 - 60 Hz | P | Kw | |
230 V | P | Kw | 7.5 |
400 V 415 V | P | Kw | 15 |
500 V | P | Kw | 15 |
690 V | P | Kw | 15 |
Rated Operating Current of Motor Load Switch | |||
230 V | Iand | One | 32 |
400 V 415 V | Iand | One | 32 |
500 V | Iand | One | 26.4 |
690 V | Iand | One | 17 |
DC | |||
DC-1, Load Switches L/R = 1 ms | |||
Rated Operating Current | Iand | One | 25 |
Torque contact voltage in series | V | 60 | |
DC-21A | Iand | One | |
Rated Operating Current | Iand | One | 1 |
Contacts | Quantity | 1 | |
DC-23A, L/R switcher motor load = 15 ms | |||
24 V | |||
Rated Operating Current | Iand | One | 25 |
Contacts | Quantity | 1 | |
48 V | |||
Rated Operating Current | Iand | One | 25 |
Contacts | Quantity | 2 | |
60 V | |||
Rated Operating Current | Iand | One | 25 |
Contacts | Quantity | 3 | |
120 V | |||
Rated Operating Current | Iand | One | 12 |
Contacts | Quantity | 3 | |
240 V | |||
Rated Operating Current | Iand | One | 5 |
Contacts | Quantity | 5 | |
DC-13, L/R Control Switches = 50 ms | |||
Rated Operating Current | Iand | One | 20 |
Torque contact voltage in series | V | 24 | |
Reliability Control Circuit at 24 VDC, 10 mA | The probability of failure | HF | < 10-5, < 1 failure in 100000 operations |
| Capacity terminal | |||
Solid or braided | mm2 | 1 x (1 - 6) 2 x (1 - 6) | |
Flexible with ferrules according to DIN 46228 | mm2 | 1 x (0.75 - 4) 2 x (0.75 - 4) | |
Screw Terminal | M4 | ||
Max. torque | Nm | 1.6 | |
| Safety Technician Parameters: | |||
Notes | B10dvalues according to EN ISO 13849-1, table C1 | ||
| Sorting Data for Approved Types | |||
Contacts | |||
Rated Operating Voltage | Uand | V AC | 600 |
Maximum uninterruptible current rating. | |||
Main the realization of routes of | |||
General Purpose | IU | One | 25 |
Auxiliary Contacts | |||
General Purpose | IU | One | 10 |
Pilot Service | A 600 P 600 | ||
Switching capacity | |||
Maximum engine power | |||
Single-phase | |||
120 V AC | HP | 1.5 | |
200 V AC | HP | 3 | |
240 V AC | HP | 3 | |
Three-phase | |||
200 V AC | HP | 3 | |
240 V AC | HP | 3 | |
480 V AC | HP | 7.5 | |
600 V AC | HP | 10 | |
Short-circuit current rating | SCCR | ||
Basics of notation | Ka | 5 | |
Max. Fuse | One | 40 | |
High Rating Defect | Ka | 10 | |
Max. Fuse | One | 40, of class J | |
Terminal Capacity | |||
Solid or Flexible Conductor with Cap | AWG | 14 - 10 | |
Screw Terminal | M4 | ||
Tightening torque | lb-in | 17.6 | |
| Product Standards | UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking | ||
| UL File No. | E36332 | ||
| UL Control Category No. | NLRV | ||
| CSA File No. | 12528 | ||
| CSA Class No. | 3211-05 | ||
| North America Certification | UL listed, CSA certified | ||
| Suitable for | Circuits, adequate, as the engine is disconnected | ||
| Degree of Protection | IEC: IP65; UL/CSA Type 1, 12 |