EATON - MOELLER NZMS2-PX300-TZ-SVE NZMS2-PX300-TZ-SVE 192195 EATON ELECTRIC NZM2 PXR25 Automatic Int. Class 1 Power Reading, 300A, 3p, Screw Te.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

NZMS2-PX300-TZ-SVE 192195 EATON ELECTRIC NZM2 PXR25 Automatic Int. Class 1 Power Reading, 300A, 3p, Screw Te..

NZMS2-PX300-TZ-SVE

192195

EATON - MOELLER

1 Pcs.

NZM2 PXR25 Automatic Int. - Class 1 Power Reading, 300A, 3p, Screw Terminal, Ground Fault Protection and ZSI, Plug-in Version The xEffect NZM...-PX...-TZ circuit breaker range with power expert release (PXR) electronic triggering system covers use cases for full range protection including grounding protection with only four compact sizes and is suitable for the IEC market. The integrated energy measuring function supplies currents, voltages and active energy (kWh) with accuracy class 1 according to IEC 61557-12. Zone selectivity for extended protection included. Test function and settings via micro USB port directly on the switch. Modular function groups always make mounting flexible and may be supplemented by the comprehensive range of accessories . RMS value measurement and thermal memory

Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers NZM

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An Eaton Moeller NZMS2-PX300-TZ-SVE circuit breaker provides reliable overcurrent protection and fault isolation within commercial and industrial electrical distribution systems. These automatic circuit breakers help prevent equipment damage by interrupting dangerous current overloads before they impact downstream networks.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Rated permanent current Iu (EF001389): 300 A
  • Rated voltage (EF003977): 690 V
  • Overload release current setting (EF002336): 120 A
  • Adjustment range undelayed short-circuit release (EF007131): 600 A
  • Device construction (EF008240): Built-in device plug-in technique
  • Integrated earth fault protection (EF007296): Yes
  • Suitable for DIN rail (top hat rail) mounting (EF007250): No
  • DIN rail (top hat rail) mounting optional (EF008904): No
  • With switched-off indicator (EF007006): No
  • With integrated under voltage release (EF001390): No
  • Number of poles (EF001391): 3
  • Position of connection for main current circuit (EF006671): Connection at separate chassis part
  • Type of control element (EF006976): Rocker lever
  • Complete device with protection unit (EF008906): Yes
  • Motor drive integrated (EF006697): No
  • Motor drive optional (EF007386): Yes

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.