| Product Name | Eaton Moeller series NZM molded case circuit breaker electronic |
| Catalog Number | 189664 |
| Model Code | NZMN4-4-PX1250/VAR-AVE |
| EAN | 4015081876112 |
| Product Length/Depth | 501 mm |
| Product Height | 280 mm |
| Product Width | 330 mm |
| Product Weight | 35.5 kg |
| Compliances | RoHS conform |
| Certifications | IEC/EN 60947 IEC |
| Application | Use in unearthed supply systems at 525 V |
| Type | Circuit breaker |
| Circuit breaker frame type | NZM4 |
| Accessories required | NZM4-4-XAVS |
| Number of poles | Four-pole |
| Amperage Rating | 1250 A |
| Release system | Electronic release |
| Features | Motor drive optional Protection unit |
| Special features |
|
| Voltage rating | 690 V - 690 V |
| Rated impulse withstand voltage (Uimp) at auxiliary contacts | 6000 V |
| Rated impulse withstand voltage (Uimp) at main contacts | 8000 V |
| Current rating of neutral conductor | 0 - 60% - 100% of phase conductor |
| Rated short-time withstand current (t = 0.3 s) | 19.2 kA |
| Rated short-time withstand current (t = 1 s) | 19.2 kA |
| Amperage Rating | 1250 A |
| Instantaneous current setting (Ii) - min | 2500 A |
| Instantaneous current setting (Ii) - max | 37500 A |
| Overload current setting (Ir) - min | 630 A |
| Overload current setting (Ir) - max | 1250 A |
| Short delay current setting (Isd) - min | 2 A |
| Short delay current setting (Isd) - max | 10 A |
| Short-circuit release delayed setting - min | 1260 A |
| Short-circuit release delayed setting - max | 12500 A |
| Short-circuit release non-delayed setting - min | 2500 A |
| Short-circuit release non-delayed setting - max | 18750 A |
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz | 37 kA |
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz | 37 kA |
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz | 26 kA |
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz | 19 kA |
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz | 15 kA |
| Rated short-circuit making capacity Icm at 240 V, 50/60 Hz | 105 kA |
| Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz | 105 kA |
| Rated short-circuit making capacity Icm at 440 V, 50/60 Hz | 74 kA |
| Rated short-circuit making capacity Icm at 525 V, 50/60 Hz | 53 kA |
| Rated short-circuit making capacity Icm at 690 V, 50/60 Hz | 40 kA |
| Short-circuit total breaktime | < 25 ms (≦ 415 V); < 35 ms (> 415 V) |
| Electrical connection type of main circuit | Other |
| Isolation | 500 V AC (between auxiliary contacts and main contacts) 300 V AC (between the auxiliary contacts) |
| Number of operations per hour - max | 60 |
| Handle type | Rocker lever |
| Utilization category | B (IEC/EN 60947-2) |
| Overvoltage category | III |
| Pollution degree | 3 |
| Lifespan, electrical | 3000 operations at 415 V AC-1 2000 operations at 690 V AC-1 3000 operations at 400 V AC-1 |
| Direction of incoming supply | As required |
| Mounting Method | Withdrawable Built-in device slide-in technique (withdrawable) |
| Mounting Method | Withdrawable Built-in device slide-in technique (withdrawable) |
| Degree of protection | IP20 IP20 (basic degree of protection, in the operating controls area) |
| Degree of protection (IP), front side | IP66 (with door coupling rotary handle) IP40 (with insulating surround) |
| Degree of protection (terminations) | IP00 (terminations, phase isolator and strip terminal) IP10 (tunnel terminal) |
| Protection against direct contact | Finger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110 |
| Shock resistance | 15 g (half-sinusoidal shock 11 ms) |
| Number of auxiliary contacts (change-over contacts) | 0 |
| Number of auxiliary contacts (normally closed contacts) | 0 |
| Number of auxiliary contacts (normally open contacts) | 0 |
| Position of connection for main current circuit | Connection at separate chassis part |
| Climatic proofing | Damp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78 |
| Special features |
|
| Lifespan, mechanical | 10000 operations |
| Standard terminals | Screw terminal |
| Optional terminals | Connection on rear. Strip terminal. Tunnel terminal |
| Terminal capacity (control cable) | 0.75 mm² - 2.5 mm² (1x) 0.75 mm² - 1.5 mm² (2x) |
| Terminal capacity (aluminum stranded conductor/cable) | 50 mm² - 240 mm² (4x) at 4-hole tunnel terminal |
| Terminal capacity (copper busbar) | Min. 25 mm x 5 mm at rear-side 1-hole module plate Min. 60 mm x 10 mm at rear-side width extension 50 mm x 10 mm (2x) at rear-side 2-hole module plate Min. 25 mm x 5 mm direct at switch rear-side connection Max. 50 mm x 10 mm (2x) at rear-side 1-hole module plate M10 at rear-side screw connection Max. 80 mm x 10 mm (2x) at rear-side width extension Max. 50 mm x 10 mm (2x) direct at switch rear-side connection |
| Terminal capacity (copper solid conductor/cable) | 300 mm² (4x) at rear-side width extension 35 mm² - 185 mm² (4x) at rear-side 2-hole module plate 95 mm² - 185 mm² (2x) at rear-side 2-hole module plate 50 mm² - 240 mm² (4x) at 4-hole tunnel terminal 95 mm² - 300 mm² (2x) at rear-side 1-hole module plate 95 mm² - 240 mm² (6x) at rear-side width extension 120 mm² - 300 mm² (1x) at rear-side 1-hole module plate |
| Terminal capacity (copper stranded conductor/cable) | 50 mm² - 185 mm² (4x) direct at switch rear-side connection 120 mm² - 185 mm² (1x) direct at switch rear-side connection |
| Terminal capacity (copper strip) | Max. 10 segments of 50 mm x 1 mm (2x) at rear-side connection (punched) 10 segments of 50 mm x 1 mm (2x) at 1-hole module plate 10 segments of 80 mm x 1 mm (2x) at rear-side width extension Max. 10 segments of 32 mm x 1 mm (2x) at flat conductor terminal Min. 6 segments of 16 mm x 0.8 mm at flat conductor terminal Min. 5 segments of 25 mm x 1 mm at rear-side connection (punched) |
| Rated operational current for specified heat dissipation (In) | 1250 A |
| Equipment heat dissipation, current-dependent | 173.44 W |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature - max | 70 °C |
| Ambient storage temperature - min | 40 °C |
| Ambient storage temperature - max | 70 °C |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Functions | Systems, cable, selectivity and generator protection |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1250 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 37 kA |
| Overload release current setting (EF002336) | 630 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 2 A |
| Adjustment range undelayed short-circuit release (EF007131) | 2500 A |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Other |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Rocker lever |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |