EATON - MOELLER NZMN2-PX300-BT NZMN2-PX300-BT 192051 EATON ELECTRIC NZM2 PXR25 Automatic Input Class 1 Power Reading, 300A, 3p, Terminal Box View larger
Images are for illustrative purposes only. Please refer to data sheet for details

NZMN2-PX300-BT 192051 EATON ELECTRIC NZM2 PXR25 Automatic Input Class 1 Power Reading, 300A, 3p, Terminal Box

NZMN2-PX300-BT

192051

EATON - MOELLER

1 Pcs.

NZM2 PXR25 Automatic Input - Class 1 Power Reading, 300A, 3p, Terminal Box The xEffect NZM...-PX circuit breaker series with Power Expert Release (PXR) electronic triggering system covers a full range of protection applications with only four compact sizes and is suitable for the IEC market. The integrated energy measuring function supplies currents, voltages and active energy (kWh) with accuracy class 1 according to IEC 61557-12. Test function and settings via micro USB port directly on the switch. Modular function groups always make mounting flexible and may be supplemented by the comprehensive range of accessories. RMS value measurement and thermal memory

Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers NZM

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The NZMN2-PX300-BT 192051 EATON ELECTRIC NZM2 PXR25 Automatic Input Class 1 Power Reading, 300A, 3p, Terminal Box functions as an advanced molded case circuit breaker equipped to protect electrical circuits from overloads and short circuits while monitoring power consumption. Facilities deploy these units within electrical distribution systems to ensure reliable safety tripping and accurate energy measurement. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Rated permanent current Iu (EF001389): 300 A
  • Rated voltage (EF003977): 690 V
  • Overload release current setting (EF002336): 120 A
  • Adjustment range undelayed short-circuit release (EF007131): 600 A
  • Device construction (EF008240): Built-in device fixed built-in technique
  • Integrated earth fault protection (EF007296): No
  • Type of electrical connection of main circuit (EF006819): Frame clamp
  • Suitable for DIN rail (top hat rail) mounting (EF007250): No
  • DIN rail (top hat rail) mounting optional (EF008904): Yes
  • With switched-off indicator (EF007006): No
  • With integrated under voltage release (EF001390): No
  • Number of poles (EF001391): 3
  • Position of connection for main current circuit (EF006671): Front
  • Type of control element (EF006976): Rocker lever
  • Complete device with protection unit (EF008906): Yes
  • Motor drive integrated (EF006697): No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.