NZML3-PMX350 189705 EATON ELECTRIC NZM3 PXR25 Automatic Int. Class 1 Power Reading, 350A, 3p, Screw Terminal

NZML3-PMX350

189705

EATON - MOELLER

1 Pcs.

NZM3 PXR25 Automatic Int. - Class 1 Power Reading, 350A, 3p, Screw Terminal Circuit-breaker, Motor protection, IEC, Fixed, Electronic release, IEC/EN 60947-4-1, IEC/EN 60947-2, The circuit-breaker fulfills all requirements for AC-3 switching category., R.m.s. value measurement and “thermal memory”, adjustable time delay setting to overcome current peaks tr: 2 – 20 s at 6 x Ir also infinity (without overload releases), All AC-3 rating data applies to direct switching by the circuit-breaker under normal operating conditions . If, for example, a contactor takes over AC-3 switching under normal operating conditions, the full rated uninterrupted current applies to the circuit-breaker, In = Iu., 3 pole, Screw terminal, Rated current = rated uninterrupted current: In = Iu 350 A, Ii = In x … 2 - 14

Automation > Motor protection circuit-breaker
Circuit Breakers NZM

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Automatic circuit-breaker model NZML3-PMX350 by Eaton Moeller integrates advanced PXR electronic trip units for precise power monitoring and fault management. These units are deployed in high-capacity electrical distribution systems to protect critical facility assets.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Overload release current setting (EF002336): 140 A
  • Adjustment range undelayed short-circuit release (EF007131): 2 A
  • With thermal overload protection (EF006233): Yes
  • Phase failure sensitive (EF007400): Yes
  • Switch off technique (EF007007): Electronic
  • Rated operating voltage (EF001435): 690 V
  • Rated permanent current Iu (EF001389): 350 A
  • Rated operation power at AC-3, 230 V (EF007025): 110 kW
  • Rated operation power at AC-3, 400 V (EF001364): 200 kW
  • Type of electrical connection of main circuit (EF006819): Screw connection
  • Type of control element (EF006976): Rocker lever
  • Device construction (EF008240): Built-in device fixed built-in technique
  • With integrated auxiliary switch (EF001387): No
  • With integrated under voltage release (EF001390): No
  • Number of poles (EF001391): 3
  • Degree of protection (IP) (EF005474): IP20