EATON - MOELLER NZML2-PMX90 NZML2-PMX90 189702 EATON ELECTRIC NZM2 PXR25 Automatic Int. Class 1, 90A, 3p Power Reading, Screw Terminal View larger
Images are for illustrative purposes only. Please refer to data sheet for details

NZML2-PMX90 189702 EATON ELECTRIC NZM2 PXR25 Automatic Int. Class 1, 90A, 3p Power Reading, Screw Terminal

NZML2-PMX90

189702

EATON - MOELLER

1 Pcs.

NZM2 PXR25 Automatic Int. - Class 1, 90A, 3p Power Reading, Screw Terminal Circuit-breaker, Motor protection, IEC, Fixed, Electronic release, IEC/EN 60947-4-1, IEC/EN 60947-2, The circuit-breaker fulfills all requirements for AC-3 switching category., R.m.s. value measurement and “thermal memory”, adjustable time delay setting to overcome current peaks tr: 2 – 20 s at 6 x Ir also infinity (without overload releases), All AC-3 rating data applies to direct switching by the circuit-breaker under normal operating conditions . If, for example, a contactor takes over AC-3 switching under normal operating conditions, the full rated uninterrupted current applies to the circuit-breaker, In = Iu., 3 pole, Screw terminal, Rated current = rated uninterrupted current: In = Iu 90 A, Ii = In x … 2 - 14

Automation > Motor protection circuit-breaker
Circuit Breakers NZM

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info


ETIM for 189702 Low-voltage industrial controls and switchgear (EC000074)
Feature Name Feature Value
Overload release current setting (EF002336) 36 A
Adjustment range undelayed short-circuit release (EF007131) 180 A
With thermal overload protection (EF006233) Yes
Phase failure sensitive (EF007400) Yes
Switch off technique (EF007007) Electronic
Rated operating voltage (EF001435) 690 V
Rated permanent current Iu (EF001389) 90 A
Rated operation power at AC-3, 230 V (EF007025) 22 kW
Rated operation power at AC-3, 400 V (EF001364) 45 kW
Type of electrical connection of main circuit (EF006819) Screw connection
Type of control element (EF006976) Rocker lever
Device construction (EF008240) Built-in device fixed built-in technique
With integrated auxiliary switch (EF001387) No
With integrated under voltage release (EF001390) No
Number of poles (EF001391) 3
Rated short-circuit breaking capacity Icu at 400 V, AC (EF007049) 130 kA
Degree of protection (IP) (EF005474) IP20
Height (EF000040) 149 mm
Width (EF000008) 105 mm
Depth (EF000049) 184 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.