View larger
NZMH2-PX250-NA
192579
Y7-192579
EATON - MOELLER
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Product Name | Eaton Moeller series NZM molded case circuit breaker electronic |
| Catalog Number | 192579 |
| Model Code | NZMH2-PX250-NA |
| EAN | 4015081933075 |
| Product Length/Depth | 149 mm |
| Product Height | 195 mm |
| Product Width | 105 mm |
| Product Weight | 2.345 kg |
| Compliances | RoHS conform |
| Certifications | CE marking UL listed UL/CSA IEC 60947-2 IEC UL (Category Control Number DIVQ) UL (File No. E31593) CSA certified CSA-C22.2 No. 5-09 Specially designed for North America UL 489 IEC/EN 60947 CSA (File No. 22086) CSA (Class No. 1432-01) |
| Application | Branch circuits, feeder circuits |
| Type |
|
| Circuit breaker frame type | NZM2 |
| Number of poles | Three-pole |
| Amperage Rating | 250 A |
| Release system | Electronic release |
| Features | Protection unit Motor drive optional |
| Special features | Circuit breaker |
| Voltage rating | 690 V - 690 V |
| Rated operating voltage Ue (UL) - max | 600 V |
| Rated impulse withstand voltage (Uimp) at auxiliary contacts | 6000 V |
| Rated impulse withstand voltage (Uimp) at main contacts | 8000 V |
| Rated operational current | 300 A (415 V AC-1, making and breaking capacity) 250 A (660-690 V AC-3, making and breaking capacity) 300 A (380/400 V AC-1, making and breaking capacity) 300 A (690 V AC-1, making and breaking capacity) |
| Rated short-time withstand current (t = 0.3 s) | 1.9 kA |
| Rated short-time withstand current (t = 1 s) | 1.9 kA |
| Amperage Rating | 250 A |
| Instantaneous current setting (Ii) - min | 2 A |
| Instantaneous current setting (Ii) - max | 12 A |
| Overload current setting (Ir) - min | 100 A |
| Overload current setting (Ir) - max | 250 A |
| Short delay current setting (Isd) - min | 500 A |
| Short delay current setting (Isd) - max | 2500 A |
| Short-circuit release delayed setting - min | 200 A |
| Short-circuit release delayed setting - max | 2500 A |
| Short-circuit release non-delayed setting - min | 500 A |
| Short-circuit release non-delayed setting - max | 3000 A |
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz | 150 kA |
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz | 150 kA |
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz | 130 kA |
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 525 V, 50/60 Hz | 37.5 kA |
| Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 690 V, 50/60 Hz | 5 kA |
| Rated short-circuit making capacity Icm at 240 V, 50/60 Hz | 330 kA |
| Rated short-circuit making capacity Icm at 400/415 V, 50/60 Hz | 330 kA |
| Rated short-circuit making capacity Icm at 440 V, 50/60 Hz | 286 kA |
| Rated short-circuit making capacity Icm at 525 V, 50/60 Hz | 105 kA |
| Rated short-circuit making capacity Icm at 690 V, 50/60 Hz | 40 kA |
| Short-circuit total breaktime | < 10 ms |
| Electrical connection type of main circuit | Screw connection |
| Isolation | 300 V AC (between the auxiliary contacts) 500 V AC (between auxiliary contacts and main contacts) |
| Number of operations per hour - max | 120 |
| Handle type | Rocker lever |
| Utilization category | A (IEC/EN 60947-2) |
| Overvoltage category | III |
| Pollution degree | 3 |
| Lifespan, electrical | 10000 operations at 400 V AC-1 6500 operations at 400 V AC-3 5000 operations at 690 V AC-3 7500 operations at 690 V AC-1 6500 operations at 415 V AC-3 |
| Direction of incoming supply | As required |
| Mounting Method | Built-in device fixed built-in technique Fixed DIN rail (top hat rail) mounting optional |
| Mounting Method | Built-in device fixed built-in technique Fixed DIN rail (top hat rail) mounting optional |
| Degree of protection | IP20 (basic degree of protection, in the operating controls area) IP20 |
| Degree of protection (IP), front side | IP40 (with insulating surround) IP66 (with door coupling rotary handle) |
| Degree of protection (terminations) | IP00 (terminations, phase isolator and strip terminal) IP10 (tunnel terminal) |
| Protection against direct contact | Finger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110 |
| Shock resistance | 20 g (half-sinusoidal shock 20 ms) |
| Number of auxiliary contacts (change-over contacts) | 0 |
| Number of auxiliary contacts (normally closed contacts) | 0 |
| Number of auxiliary contacts (normally open contacts) | 0 |
| Position of connection for main current circuit | Front side |
| Climatic proofing | Damp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78 |
| Special features | Circuit breaker |
| Lifespan, mechanical | 20000 operations |
| Standard terminals | Screw terminal |
| Terminal capacity (copper busbar) | M8 at rear-side screw connection |
| Terminal capacity (copper solid conductor/cable) | 16 mm² (1x) at tunnel terminal |
| Rated operational current for specified heat dissipation (In) | 250 A |
| Equipment heat dissipation, current-dependent | 51.56 W |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature - max | 70 °C |
| Ambient storage temperature - min | 40 °C |
| Ambient storage temperature - max | 70 °C |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Functions | Systems, cable, selectivity and generator protection |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 250 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 150 kA |
| Overload release current setting (EF002336) | 100 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 500 A |
| Adjustment range undelayed short-circuit release (EF007131) | 2 A |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | Yes |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Rocker lever |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |