NZMS3-4-VE400/250-AVE 113562 Y7-113562 EATON ELECTRIC Power Distribution Components IEC Moulded case circuit..
NZMS3-4-VE400/250-AVE
113562
Y7-113562
EATON - MOELLER
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Eaton Moeller NZMS3-4-VE400/250-AVE moulded case circuit breaker provides heavy-duty power distribution control and automated fault interruption for industrial installations. It is engineered to protect major electrical feeders and equipment from overloads and short circuits.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 400 A
- Rated voltage (EF003977): 690 V
- Overload release current setting (EF002336): 200 A
- Adjustment range undelayed short-circuit release (EF007131): 800 A
- Power loss (EF005387): None W
- Device construction (EF008240): Built-in device slide-in technique (withdrawable)
- Integrated earth fault protection (EF007296): false
- Type of electrical connection of main circuit (EF006819): Screw connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): false
- DIN rail (top hat rail) mounting optional (EF008904): false
- With switched-off indicator (EF007006): false
- With integrated under voltage release (EF001390): false
- Number of poles (EF001391): 4
- Position of connection for main current circuit (EF006671): Back side
- Type of control element (EF006976): Rocker lever
- Complete device with protection unit (EF008906): true
More info
▲General specifications
IEC/EN 60947
Product specifications
Protection unit
Built-in device slide-in technique (withdrawable)
Damp heat, cyclic, to IEC 60068-2-30
500 V AC (between auxiliary contacts and main contacts)
IP20 (basic degree of protection, in the operating controls area)
60% of phase conductor
IP40 (with insulating surround)
IP00 (terminations, phase isolator and strip terminal)
Min. 6 segments of 16 mm x 0.8 mm at rear-side connection (punched)
10 segments of 50 mm x 1 mm (2x) at rear-side width extension
Max. 10 segments of 24 mm x 1 mm + 5 segments of 24 mm x 1 mm
Max. 10 segments of 32 mm x 1 mm + 5 segments of 32 mm x 1 mm at rear-side connection (punched)
Max. 8 segments of 24 mm x 1 mm (2x) at box terminal
Min. 6 segments of 16 mm x 0.8 mm at box terminal
3000 operations at 690 V AC-1
2000 operations at 400 V AC-3
5000 operations at 400 V AC-1
1000 operations at 690 V AC-3
2000 operations at 415 V AC-1
0.75 mm² - 1.5 mm² (2x)
M10 at rear-side screw connection
Max. 30 mm x 10 mm + 30 mm x 5 mm direct at switch rear-side connection
Max. 10 mm x 50 mm (2x) at rear-side width extension
300 mm² (2x) at rear-side width extension
16 mm² (1x) direct at switch rear-side connection
16 mm² (2x) direct at switch rear-side connection
16 mm² (2x) at box terminal
25 mm² - 120 mm² (2x) at box terminal
35 mm² - 240 mm² (1x) at box terminal
25 mm² - 240 mm² (2x) direct at switch rear-side connection
25 mm² - 240 mm² (1x) direct at switch rear-side connection
50 mm² - 240 mm² (1x) at 2-hole tunnel terminal
25 mm² - 185 mm² (1x) at tunnel terminal