View larger
NZMS3-4-AE630/400-AVE 113560 Y7-113560 EATON ELECTRIC Circuit-breaker 4-pole 630 A, system/cable protection,..
NZMS3-4-AE630/400-AVE
113560
Y7-113560
EATON - MOELLER
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Molded case circuit breakers like the Eaton Moeller NZMS3-4-AE630/400-AVE 113560 Y7-113560 EATON ELECTRIC Circuit-breaker 4-pole 630 A, system/cable protection,.. are deployed in electrical distribution systems to safeguard conductors and connected loads against excessive current draw. By interrupting faulty currents, they prevent equipment damage and maintain the safety of electrical infrastructure.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 630 A
- Rated voltage (EF003977): 690 V
- Overload release current setting (EF002336): 315 A
- Adjustment range undelayed short-circuit release (EF007131): 1260 A
- Device construction (EF008240): Built-in device slide-in technique (withdrawable)
- Integrated earth fault protection (EF007296): No
- Type of electrical connection of main circuit (EF006819): Screw connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): No
- DIN rail (top hat rail) mounting optional (EF008904): No
- With switched-off indicator (EF007006): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 4
- Position of connection for main current circuit (EF006671): Back
- Type of control element (EF006976): Rocker lever
- Complete device with protection unit (EF008906): Yes
- Motor drive integrated (EF006697): No
More info
▲General specifications
IEC
Product specifications
Protection unit
Built-in device slide-in technique (withdrawable)
Damp heat, constant, to IEC 60068-2-78
300 V AC (between the auxiliary contacts)
IP20
400 A
IP66 (with door coupling rotary handle)
IP00 (terminations, phase isolator and strip terminal)
Max. 8 segments of 24 mm x 1 mm (2x) at box terminal
Min. 6 segments of 16 mm x 0.8 mm at box terminal
Min. 6 segments of 16 mm x 0.8 mm at rear-side connection (punched)
Max. 10 segments of 32 mm x 1 mm + 5 segments of 32 mm x 1 mm at rear-side connection (punched)
10 segments of 50 mm x 1 mm (2x) at rear-side width extension
2000 operations at 415 V AC-3
2000 operations at 690 V AC-3
5000 operations at 400 V AC-1
5000 operations at 415 V AC-1
3000 operations at 690 V AC-1
0.75 mm² - 2.5 mm² (1x)
Max. 10 mm x 50 mm (2x) at rear-side width extension
Max. 30 mm x 10 mm + 30 mm x 5 mm direct at switch rear-side connection
Min. 20 mm x 5 mm direct at switch rear-side connection
16 mm² (1x) direct at switch rear-side connection
16 mm² (2x) direct at switch rear-side connection
16 mm² (2x) at box terminal
16 mm² (1x) at tunnel terminal
16 mm² - 185 mm² (1x) at 1-hole tunnel terminal
25 mm² - 120 mm² (2x) at box terminal
25 mm² - 240 mm² (2x) direct at switch rear-side connection
35 mm² - 240 mm² (1x) at box terminal
50 mm² - 240 mm² (1x) at 2-hole tunnel terminal
50 mm² - 240 mm² (2x) at 2-hole tunnel terminal