NZM2/3-XUHIV2A110-130AC 189734 Y7-189734 EATON ELECTRIC NZM2/3-XUHIV2A110-130AC
NZM2/3-XUHIV2A110-130AC
189734
Y7-189734
EATON - MOELLER
1 Pcs.
Automation > Under voltage coil
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller NZM2/3-XUHIV2A110-130AC 189734 Y7-189734 EATON ELECTRIC NZM2/3-XUHIV2A110-130AC undervoltage release monitors line stability while providing integrated auxiliary contact switching.
These modules are typically integrated into power distribution arrays to drop out circuit protection elements automatically during a voltage sag event. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 110 V
- Rated control supply voltage AC 60 Hz (EF003979): 110 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Type of electric connection (EF003961): Screw connection
- Number of contacts as normally open contact (EF008256): 3
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as change-over contact (EF008257): 0
- Delayed (EF001541): No
- Suitable for power circuit breaker (EF005863): No
- Suitable for off-load switch (EF001543): Yes
- Suitable for motor safety switch (EF005826): Yes
- Suitable for overload relay (EF001545): No
More info
▲Delivery program
Non-delayed disconnection of NZM circuit-breaker or N switch-disconnector when the control voltage sinks below 35 – 70% US.
For use with emergency-stop devices in connection with an emergency-stop button.
For signalizing commands or different states of the circuit-breaker.
Two relays per unit.
The activation criteria can be configured in the trip unit.
Configuration via communication or circuit breaker display or front USB port and Eaton Power Xpert Protection Manager.
When the under-voltage trip is switched off, accidental contact with the circuit breaker’s primary contacts is prevented when switched on.
Make-before-break activation of auxiliary contact when switching on and off (manual operation): approx. 20 ms (NZM2/3) and 90 ms (NZM4).
Only for use in combination with circuit-breakers with electronic trips.
Cannot be used in conjunction with NZM...-XR... remote operator.
Under-voltage trip relay modules cannot be installed simultaneously with make-before-break auxiliary contact NZM...-XHIV, under-voltage trip NZM...-XU... or shunt trip NZM...-XA.
Relay coil is controlled by trip unit.
Relay contacts for control wiring.
Relays can be used for controlling remote operator with Us=208-204 V AC.
Control wiring on push-in clamps.
Cannot be used with the PXR10 NZM-AX electronic trip.
PXR20(25) NZM3(-4)-..X…