View larger
NZM2/3-XA2A24AC/DC 189740 Y7-189740 EATON ELECTRIC NZM2/3-XA2A24AC/DC
NZM2/3-XA2A24AC/DC
189740
Y7-189740
EATON - MOELLER
1 Pcs.
Automation > Shunt release (for power circuit breaker)
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A shunt release accessory is an electromechanical device mounted inside circuit breakers to remotely trip the switchgear upon receiving an external voltage signal, providing essential emergency stop capabilities in industrial power architecture. This Eaton Moeller NZM2/3-XA2A24AC/DC unit interfaces directly with control loops to interrupt power safely.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage AC 50 Hz (EF003978): 24 V
- Rated control supply voltage AC 60 Hz (EF003979): 24 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): AC/DC
- Type of electric connection (EF003961): Spring clamp connection
- Number of contacts as normally open contact (EF008256): 2
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as change-over contact (EF008257): 0
- Suitable for power circuit breaker (EF005863): No
- Suitable for off-load switch (EF001543): Yes
- Suitable for motor safety switch (EF005826): Yes
- Suitable for overload relay (EF001545): No
More info
▲General specifications
IEC
RoHS conform
CSA-C22.2 No. 5-09
IEC60947
CSA (File No. 22086)
CSA certified
UL listed
CSA (Class No. 1437-01)
UL (Category Control Number DIHS)
UL489
CE marking
Product specifications
- The breakers are actuated by a voltage pulse or by applying a no-break current.
- For signalizing commands or different states of the circuit-breaker.
- Two relays per unit.
- The activation criteria can be configured in the trip unit.
- Configuration via communication or circuit breaker display or front USB port and Eaton Power Xpert Protection Manager.
- If the shunt trip is live, contact with the circuit breaker’s primary contacts is prevented when switched on.
- Only for use in combination with circuit-breakers with electronic trips.
- Shunt trip relay modules cannot be installed simultaneously with make-before-break auxiliary contact NZM...-XHIV, under-voltage trip NZM...-XU... or shunt trip NZM...-XA.
- Relay coil is controlled by trip unit.
- Relay contacts for control wiring.
- Relays can be used for controlling remote operator with Us=208-204 V AC.
- Control wiring on push-in clamps.
- Cannot be used with the PXR10 NZM-AX electronic trip.
PXR20(25) NZM3(-4)-..X…
Off-load switch
1 A (230 V AC-1, relay contacts)
1 A (24 V AC-1, relay contacts)
24 - 16 AWG (1x) for undervoltage release
0.25 mm² - 1.5 mm² (1x) at shunt release (insulated ferrule according to DIN46224 / 4)
0.25 mm² - 1.5 mm² (1x) at shunt release
24 - 16 AWG (1x) at shunt release
0.25 mm² - 1.5 mm² (1x) for undervoltage release
0.2 mm² - 1.5 mm² (1x) for undervoltage release
24 V DC
240 V AC