EATON - MOELLER N-P1Z N-P1Z 000652 Y7-652 EATON ELECTRIC Neutral conductor, 4th pole, N for P1Z View larger
Images are for illustrative purposes only. Please refer to data sheet for details

N-P1Z 000652 Y7-652 EATON ELECTRIC Neutral conductor, 4th pole, N for P1Z

N-P1Z

000652

Y7-652

EATON - MOELLER

1 Pcs.

Neutral conductor, 4th pole, N for P1Z Module for Neutral conductor; 4th poles; For P1-.../Z Eaton Moeller® series Neutral conductor, 4th pole, N for P1Z Accessories to cam switches T/switch-disconnectors P according to IEC/EN60947-3, design general: insulating material-surface mounting enclosure , flush mounting, center mounting, rear mounting IVS service distribution board mounting. The capable, robust, compact T cam switches are used in industry, handwork, and building services management. A variety of standard circuits are available for selection. Special customer-specific circuits are implemented as supplements. The possibilities are almost unlimited here. Comprehensive accessories complete the switch range and supplement application possibilities.

Automation > Accessories/spare parts for low-voltage switch technology
Disconnectors and Cam Switches

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Moeller® series Accessory Neutral conductor
Catalog Number
000652
Model Code
N-P1Z
EAN
4015080006527
Product Length/Depth
32 mm
Product Height
70 mm
Product Width
15 mm
Product Weight
0.03 kg
Certifications
CSA-C22.2 No. 14-05
UL Category Control No.: NLRV
CSA-C22.2 No. 94
CSA
UL File No.: E36332
CE
UL 508
CSA File No.: 012528
IEC/EN 60947-3
UL
CSA Class No.: 3211-05

General

Accessory/spare part type
Neutral terminal
Mounting position
Left side
Right side
Type

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
50 °C

Terminal capacities

Stripping length (main cable)
10.5 mm

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
1.8 W
Rated operational current for specified heat dissipation (In)
32 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 000652 Low-voltage industrial controls and switchgear (EC002498)
Feature Name Feature Value
Type of accessory/spare part (EF000215) Neutral terminal
Accessory (EF013236) Yes
Spare part (EF013237) No

Product Datasheet