View larger
N2-160-BT 110311 Y7-110311 EATON ELECTRIC Switch-disconnector 3p 160A terminals
N2-160-BT
110311
Y7-110311
EATON - MOELLER
1 Pcs.
Connectors > Switch disconnector
Circuit Breakers NZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller N2-160-BT switch-disconnector functions as a robust mechanical circuit disconnecting device for high-amperage industrial electrical installations. These units are deployed in heavy-duty distribution systems to safely isolate equipment during servicing or emergency conditions. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Version as main switch (EF006981): Yes
- Version as maintenance-/service switch (EF006986): Yes
- Version as safety switch (EF006985): No
- Version as emergency stop installation (EF006959): Yes
- Version as reversing switch (EF009408): No
- Number of switches (EF005586): 1
- Max. rated operation voltage Ue AC (EF007355): 690 V
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 160 A
- Rated permanent current at AC-23, 400 V (EF011777): 0 A
- Rated permanent current at AC-21, 400 V (EF009165): 0 A
- Rated operation power at AC-3, 400 V (EF001364): 0 kW
- Rated short-time withstand current lcw (EF007050): 3.5 kA
- Rated operation power at AC-23, 400 V (EF007027): 90 kW
- Switching power at 400 V (EF009166): 0 kW
- Conditioned rated short-circuit current Iq (EF001444): 0 kA
More info
▲General specifications
IEC
Product specifications
Version as maintenance-/service switch
Motor drive optional
Version as emergency stop installation
Ground mounting
Built-in device fixed built-in technique
Distribution board installation
Intermediate mounting
Damp heat, constant, to IEC 60068-2-78
500 V AC (between auxiliary contacts and main contacts)
Other
160 A (690 V AC-22/23A, making and breaking capacity)
IP20
IP40 (with insulating surround)
IP00 (terminations, phase isolator and band terminal)
Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched)
Max. 10 segments of 24 mm x 0.8 mm at rear-side connection (punched)
Min. 2 segments of 9 mm x 0.8 mm at box terminal
Max. 10 segments of 16 mm x 0.8 mm at box terminal
10000 operations at 400 V AC-1
5000 operations at 690 V AC-3
7500 operations at 415 V AC-3
10000 operations at 415 V AC-1
7500 operations at 690 V AC-1
Voltage release optional
Interlockable
PN2(N2)-160…250: 250 AgGgL
100 kA at 400/415 V
80 kA at 690 V
100 kA at 400/415 V
Min. 16 mm x 5 mm direct at switch rear-side connection
M8 at rear-side screw connection
6 mm² - 16 mm² (2x) direct at switch rear-side connection
16 mm² (1x) at tunnel terminal
10 mm² - 16 mm² (1x) at box terminal
10 mm² - 16 mm² (1x) direct at switch rear-side connection
16 mm² (1x) at tunnel terminal
10 mm² - 16 mm² (1x) direct at switch rear-side connection
25 mm² - 70 mm² (2x) at box terminal
25 mm² - 70 mm² (2x) direct at switch rear-side connection
25 mm² - 185 mm² (1x) at box terminal
25 mm² - 185 mm² (1x) direct at switch rear-side connection