View larger
MSC-DEA-4-M17-SP(24VDC) 167823 Y7-167823 EATON ELECTRIC Electronic control relay, rated operating voltage 24..
MSC-DEA-4-M17-SP(24VDC)
167823
Y7-167823
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Electronic Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller MSC-DEA-4-M17-SP(24VDC) electronic control relay is a compact motor starter component utilized to regulate and safeguard electrical loads in manufacturing setups. Units of this type typically provide coordinated direct-on-line starting, thermal overload protection, and short-circuit isolation for machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Direct starter
- With short-circuit release (EF006691): Yes
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Rated operation power at AC-3, 230 V, 3-phase (EF009599): 0.75 kW
- Rated operation power at AC-3, 400 V (EF001364): 7.5 kW
- Rated power, 460 V, 60 Hz, 3-phase (EF009600): 1.47 kW
- Rated power, 575 V, 60 Hz, 3-phase (EF009601): 0 kW
- Rated operation current Ie (EF001443): 16.7 A
- Rated operation current at AC-3, 400 V (EF009602): 4 A
- Overload release current setting (EF002336): 1 A
- Ambient temperature, upper operating limit (EF009603): 55 °C
- Temperature compensated overload protection (EF009604): Yes
- Release class (EF006668): Adjustable
More info
▲General specifications
CE
UL Category Control No.: NKJH
CSA Class No.: 3211-08
UL
UL60947-4-1A
CSA
UL File No.: E123500
CSA File No.: 012528
IEC/EN 60947-4-1
VDE 0660
Features & Functions
General
Yes
500 (Class 5) AC-4 cycle operation, Main conducting paths
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods.
700 (Class 10) AC-4 cycle operation, Main conducting paths
1000 (Class 20) AC-4 cycle operation, Main conducting paths
Note: Going below the minimum current flow time can cause overheating of the load (motor).
NEMA Other
Climatic environmental conditions
Electrical rating
1 A, 250 V DC, (UL/CSA)
P300, DC operated (UL/CSA)
Short-circuit rating
18 kA, 480 Y/277 V, SCCR (UL/CSA)