View larger
MSC-DEA-1,2-M17-SP(24VDC) 167822 Y7-167822 EATON ELECTRIC DOL starter, 0.3-1.2, protection electronic, advan..
MSC-DEA-1,2-M17-SP(24VDC)
167822
Y7-167822
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Electronic Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Direct starter combinations like the Eaton Moeller MSC-DEA-1,2-M17-SP(24VDC) offer advanced electronic motor protection and switching capabilities for industrial control panels. These integrated units minimize wiring efforts while providing precise overload monitoring for connected loads.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Direct starter
- With short-circuit release (EF006691): Yes
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Rated operation power at AC-3, 230 V, 3-phase (EF009599): 0.18 kW
- Rated operation power at AC-3, 400 V (EF001364): 7.5 kW
- Rated power, 460 V, 60 Hz, 3-phase (EF009600): 0.37 kW
- Rated power, 575 V, 60 Hz, 3-phase (EF009601): 0.37 kW
- Rated operation current Ie (EF001443): 16.7 A
- Rated operation current at AC-3, 400 V (EF009602): 1.2 A
- Overload release current setting (EF002336): 0.3 A
- Ambient temperature, upper operating limit (EF009603): 55 °C
- Temperature compensated overload protection (EF009604): Yes
- Release class (EF006668): Adjustable
More info
▲General specifications
CSA
CE
UL Category Control No.: NKJH
CSA File No.: 012528
IEC/EN 60947-4-1
CSA Class No.: 3211-08
CSA-C22.2 No. 14-10
VDE 0660
UL60947-4-1A
UL
Features & Functions
General
Yes
700 (Class 10) AC-4 cycle operation, Main conducting paths
900 (Class 15) AC-4 cycle operation, Main conducting paths
Note: Going below the minimum current flow time can cause overheating of the load (motor).
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods.
1000 (Class 20) AC-4 cycle operation, Main conducting paths
NEMA Other
Climatic environmental conditions
Electrical rating
15 A, 600 V AC, (UL/CSA)
A600, AC operated (UL/CSA)
Short-circuit rating
14 kA, 480 Y/277 V, SCCR (UL/CSA)