View larger
MSC-DE-32-M32-SP(24VDC) 167821 Y7-167821 EATON ELECTRIC Electronic control relay, rated operating voltage 24..
MSC-DE-32-M32-SP(24VDC)
167821
Y7-167821
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Electronic Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Configured as an electronic control relay, the Eaton Moeller MSC-DE-32-M32-SP(24VDC) serves as an integrated motor starter solution. Direct-on-line control devices of this variety are routinely deployed in manufacturing systems to regulate motor power transmission safely.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Direct starter
- With short-circuit release (EF006691): Yes
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Rated operation power at AC-3, 230 V, 3-phase (EF009599): 7.5 kW
- Rated operation power at AC-3, 400 V (EF001364): 15 kW
- Rated power, 460 V, 60 Hz, 3-phase (EF009600): 11 kW
- Rated power, 575 V, 60 Hz, 3-phase (EF009601): 0 kW
- Rated operation current Ie (EF001443): 29.3 A
- Rated operation current at AC-3, 400 V (EF009602): 32 A
- Overload release current setting (EF002336): 8 A
- Ambient temperature, upper operating limit (EF009603): 55 °C
- Temperature compensated overload protection (EF009604): Yes
- Release class (EF006668): Adjustable
More info
▲General specifications
CSA Class No.: 3211-08
IEC/EN 60947-4-1
UL
UL Category Control No.: NKJH
CE
CSA File No.: 012528
CSA-C22.2 No. 14-10
CSA
UL60947-4-1A
VDE 0660
Features & Functions
General
Note: Going below the minimum current flow time can cause overheating of the load (motor).
700 (Class 10) AC-4 cycle operation, Main conducting paths
900 (Class 15) AC-4 cycle operation, Main conducting paths
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods.
1000 (Class 20) AC-4 cycle operation, Main conducting paths
NEMA Other
Climatic environmental conditions
Electrical rating
1 A, 250 V DC, (UL/CSA)
P300, DC operated (UL/CSA)
Short-circuit rating
18 kA, 240 V, SCCR (UL/CSA)