View larger
MSC-DE-12-M17-SP(24V50/60HZ) 167816 Y7-167816 EATON ELECTRIC DOL starter, 3-12A, protection electronic, stan..
MSC-DE-12-M17-SP(24V50/60HZ)
167816
Y7-167816
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Electronic Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller MSC-DE-12-M17-SP(24V50/60HZ) functions as a direct starter designed for secure motor operation and straightforward panel integration. Industrial direct-on-line starters are standard assets in automated facilities, providing essential switching capabilities and overload protection for three-phase electric motors. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Direct starter
- With short-circuit release (EF006691): Yes
- Rated control supply voltage AC 50 Hz (EF003978): 24 V
- Rated control supply voltage AC 60 Hz (EF003979): 24 V
- Rated control supply voltage DC (EF003980): 0 V
- Voltage type for actuating (EF008242): AC
- Rated operation power at AC-3, 230 V, 3-phase (EF009599): 3 kW
- Rated operation power at AC-3, 400 V (EF001364): 7.5 kW
- Rated power, 460 V, 60 Hz, 3-phase (EF009600): 5.52 kW
- Rated power, 575 V, 60 Hz, 3-phase (EF009601): 0 kW
- Rated operation current Ie (EF001443): 16.7 A
- Rated operation current at AC-3, 400 V (EF009602): 12 A
- Overload release current setting (EF002336): 3 A
- Ambient temperature, upper operating limit (EF009603): 55 °C
- Temperature compensated overload protection (EF009604): Yes
- Release class (EF006668): Adjustable
More info
▲Delivery program
277 V
Mechanical connection element and electrical electric contact module
The DOL starter type E (complete devices) consists of a PKE motor-protective circuit-breaker with AK-PKZ0, a DILM contactor and an extension terminal BK25/3-PKZ0-E.
Motor-protective circuit-breaker and contactor mounted on top hat rail adapter plate.
The connection of the main circuit between PKE and contactor is established with electrical contact modules.
Technical data
700 (Class 10)
900 (Class 15)
1000 (Class 20) ms
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods. ms
DILM contactors, see contactor product group
208 V
240 V
480 V