View larger
MSC-DEA-4-M7(24VDC) 121754 Y7-121754 EATON ELECTRIC DOL starter, 3p, 0.55-1.5kW/400V/AC3, 100kA, protection ..
MSC-DEA-4-M7(24VDC)
121754
Y7-121754
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Electronic Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Equipped for seamless bus communication, the Eaton Moeller MSC-DEA-4-M7(24VDC) serves as an intelligent DOL starter featuring SmartWire-DT connectivity. SmartWire-enabled starters eliminate traditional control wiring bottlenecks, making them ideal for complex, data-driven automation cells. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Connection to SmartWire-DT: yes, 24 V DC, DC DOL starter
- Basic device: MSC
- Coordination: Type of coordination “1”
- Actuating voltage: 24 V DC, DC
More info
▲Delivery program
IE3-ready devices are identified by the logo on their packaging.
in conjunction with PKE-SWD-32 SmartWire DT PKE module
Mechanical connection element and electrical electric contact module
The DOL starters (complete units) consist of a PKE motor protective circuit breaker and a DILM contactor.
With the adapter-less top-hat rail mounting of starters up to 15 A, only the motor protective circuit breaker on the top-hat rail requires an adapter.
The contactors are provided with mechanical support via a mechanical connection element.
Control wire guide with max. 6 conductors up to 2.5 mm external diameter or 4 conductors up to 3.5 mm external diameter.
The connection of the main circuit between PKE and contactor is established with electrical contact modules.
When using DILA-XHIT… auxiliary contacts with MSC-DE-... DOL starters, the plug-in electrical connectors can be removed without removing the front-mounted auxiliary contact.
Cannot be combined with NHI‐E…PKZ0‐C.
The MSC-DEA... DOL starters are prepared for communication via SmartWire-DT. For this, the PKE-SWD-32 communication module must be added.
Motor rating | Rated motor current | |||||
|---|---|---|---|---|---|---|
AC-3 | ||||||
| 220 V 230 V 240 V | 380 V 400 V | 415 V | ||||
| Iq= 100 kA | Iq=100 kA | Iq= 50 kA | ||||
| P | I | I | I | |||
| kW | A | A | A | |||
| 0.18 | 1.04 | - | - | |||
| 0.25 | 1.4 | - | - | |||
| 0.37 | 2 | 1.1 | 1.1 | |||
| 0.55 | 2.7 | 1.5 | 1.5 | |||
| 0.75 | 3.2 | 1.9 | 1.9 | |||
| 1.1 | - | 2.6 | 2.6 | |||
| 1.5 | - | 3.6 | 3.6 |
Technical data
700 (Class 10)
900 (Class 15)
1000 (Class 20) ms
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods. ms
DILM contactors, see contactor product group
DILET timing relay, ETR, see contactors, electronic timing relays product group