View larger
PKE12/XTU-12 121733 Y7-121733 EATON ELECTRIC Motor-protective circuit-breaker, 3p, Ir 3-12A, standard
PKE12/XTU-12
121733
Y7-121733
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Electronic Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Motor-protective circuit-breaker PKE12/XTU-12 from Eaton Moeller is designed for 3-pole electrical systems, offering precise electronic overload monitoring and short-circuit protection for industrial motors. Such protective switching devices are commonly installed in motor control centers to safeguard machinery against operational anomalies.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 3 A
- Adjustment range undelayed short-circuit release (EF007131): 186 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): Yes
- Switch off technique (EF007007): Electronic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 12 A
- Rated operation power at AC-3, 230 V (EF007025): 3 kW
- Rated operation power at AC-3, 400 V (EF001364): 5.5 kW
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rotating button
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
UL
CSA
CSA Class No.: 3211-05
IEC/EN 60947-4-1
CSA-C22.2 No. 60947-4-1-14
UL 60947-4-1
CE
CSA File No.: 165628
VDE 0660
UL Category Control No.: NLRV
UL File No.: E36332
Features & Functions
Phase failure sensitive
Overload release
Motor protection for heavy starting duty
General
700 (Class 10) AC-4 cycle operation, Main conducting paths
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods.
Note: Going below the minimum current flow time can cause overheating of the load (motor).
500 (Class 5) AC-4 cycle operation, Main conducting paths
900 (Class 15) AC-4 cycle operation, Main conducting paths
IP20
-25 - 55 °C, Operating range
Ambient conditions, mechanical
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
1 x (1 - 6) mm², ferrule to DIN 46228
1 x (1 - 6) mm²
1 Nm, Screw terminals, Control circuit cables
Electrical rating
Short-circuit rating
100 kA, 600 V High Fault, Fuse, SCCR (UL/CSA)
Delayed approx. 60 ms, Trip blocks
± 20% tolerance, Trip blocks
Trip block fixed 15.5 x Ir
Switching capacity
12 A, AC-3 up to 690 V