View larger
PKZM4-32 222353 Y7-222353 EATON ELECTRIC Motor-protective circuit-breaker, 3p, Ir 24-32A, screw connection
PKZM4-32
222353
Y7-222353
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers PKZ
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller PKZM4-32 is a motor-protective circuit-breaker, 3p, Ir 24-32A, screw connection engineered to isolate circuits and protect industrial electric motors from thermal overloads and line faults. These devices are widely deployed in motor control centers to ensure safe startup, continuous operation, and immediate shutdown during fault conditions.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 25 A
- Adjustment range undelayed short-circuit release (EF007131): 496 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): Yes
- Switch off technique (EF007007): Thermomagnetic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 32 A
- Rated operation power at AC-3, 230 V (EF007025): 7.5 kW
- Rated operation power at AC-3, 400 V (EF001364): 15 kW
- Power loss (EF005387): 18 W
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rotating button
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
More info
▲General specifications
CSA File No.: 165628
IEC/EN 60947-4-1
UL 60947-4-1
UL Category Control No.: NLRV
UL File No.: E36332
CE
IEC/EN 60947
CSA Class No.: 3211-05
CSA-C22.2 No. 60947-4-1-14
CSA
VDE 0660
Features & Functions
Motor protection
General
Branch circuit: Manual type E if used with terminal, or suitable for group installations, (UL/CSA)
-5 - 40 °C to IEC/EN 60947, VDE 0660
≤ 0.25 %/K, residual error for T > 40°
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
2 x (0.75 - 25) mm², Main cables
2 x (0.75 - 16) mm²
Electrical rating
Short-circuit rating
600 A, 600 V High Fault, max. Fuse, SCCR (UL/CSA)
600 A, 600 V High Fault, max. CB, SCCR (UL/CSA)
42 kA, 600 V High Fault, CB, SCCR (UL/CSA)
65 kA, 480 Y/277 V, SCCR (UL/CSA)
25 kA, 600 Y/347 V, SCCR (UL/CSA)
Accessories required BK50/3-PKZ4-E
496 A, Irm, Setting range max.
Basic device fixed 15.5 x Iu, Trip Blocks