View larger
PKZM0-32
278489
Y7-278489
EATON - MOELLER
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Product Name | Eaton Moeller® series PKZM0 Motor-protective circuit-breaker |
| Catalog Number | 278489 |
| Model Code | PKZM0-32 |
| EAN | 4015082784898 |
| Product Length/Depth | 76 mm |
| Product Height | 93 mm |
| Product Width | 45 mm |
| Product Weight | 0.288 kg |
| Certifications | CSA File No.: 165628 CSA-C22.2 No. 60947-4-1-14 IEC/EN 60947 UL 60947-4-1 VDE 0660 CE UL Category Control No.: NLRV UL File No.: E36332 IEC/EN 60947-4-1 CSA Class No.: 3211-05 UL CSA |
| Actuator type | Turn button |
| Features | Phase-failure sensitivity (according to IEC/EN 60947-4-1, VDE 0660 Part 102) |
| Functions | Phase failure sensitive Motor protection |
| Number of poles | Three-pole |
| Connection | Screw terminals |
| Lifespan, electrical | 100,000 operations (at 400V, AC-3) |
| Lifespan, mechanical | 100,000 Operations (Main conducting paths) |
| Mounting position | Can be snapped on to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height. |
| Operating frequency | 40 Operations/h |
| Overvoltage category | III |
| Pollution degree | 3 |
| Product category | Motor protective circuit breaker |
| Product category | Motor protective circuit breaker |
| Protection | Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274) |
| Rated impulse withstand voltage (Uimp) | 6000 V AC |
| Shock resistance | 25 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms |
| Suitable for | Also motors with efficiency class IE3 Branch circuit: Suitable for group installations, (UL/CSA) |
| Temperature compensation | -25 - 55 °C, Operating range -5 - 40 °C to IEC/EN 60947, VDE 0660 ≤ 0.25 %/K, residual error for T > 40° |
| Altitude | Max. 2000 m |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature - max | 55 °C |
| Ambient operating temperature (enclosed) - min | -25 °C |
| Ambient operating temperature (enclosed) - max | 40 °C |
| Ambient storage temperature - min | -40 °C |
| Ambient storage temperature - max | 80 °C |
| Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
| Terminal capacity (solid) | 2 x (1 - 6) mm² 1 x (1 - 6) mm² |
| Terminal capacity (solid/stranded AWG) | 18 - 10 |
| Stripping length (main cable) | 10 mm |
| Tightening torque | 1.7 Nm, Screw terminals, Main cable 1 Nm, Screw terminals, Control circuit cables |
| Rated frequency - min | 50 Hz |
| Rated frequency - max | 60 Hz |
| Rated operational power at AC-3e, 220/230 V, 50 Hz | 7.5 kW |
| Rated operational power at AC-3e, 380/400 V, 50 Hz | 15 kW |
| Rated operational voltage (Ue) - min | 690 V |
| Rated operational voltage (Ue) - max | 690 V |
| Rated uninterrupted current (Iu) | 32 A |
| Rated short-circuit breaking capacity Icu at 400 V AC | 40 kA |
| Rated short-circuit breaking capacity Ics at 400 V AC | 10 kA |
| Rated short-circuit breaking capacity Icu at 440 V AC | 10 kA |
| Rated short-circuit breaking capacity Ics at 440 V AC | 3 kA |
| Rated short-circuit breaking capacity Icu at 500 V AC | 3 kA |
| Rated short-circuit breaking capacity Ics at 500 V AC | 3 kA |
| Rated short-circuit breaking capacity Icu at 690 V AC | 3 kA |
| Rated short-circuit breaking capacity Ics at 690 V AC | 1 kA |
| Short-circuit current | 40 kA DC, up to 250 V DC, Main conducting paths |
| Short-circuit current rating (group protection) | 10 kA, 600 V High Fault, Fuse, SCCR (UL/CSA) with 150 A, 600 V High Fault, Fuse, SCCR (UL/CSA) 10 kA, 600 V High Fault, CB, SCCR (UL/CSA) with 125 A, 600 V High Fault, CB, SCCR (UL/CSA) 18 kA, 600 V High Fault, CB with CL, SCCR (UL/CSA) with 600 A, 600 V High Fault, CB with CL, SCCR (UL/CSA) 18 kA, 600 V High Fault, Fuse with CL, SCCR (UL/CSA) with 600 A, 600 V High Fault, Fuse with CL, SCCR (UL/CSA) 18 kA, 480 V High Fault, CB, SCCR (UL/CSA) with 600 A, 480 V High Fault, CB, SCCR (UL/CSA) 18 kA, 480 V High Fault, Fuse, SCCR (UL/CSA) with 600 A, 480 V High Fault, Fuse, SCCR (UL/CSA) |
| Short-circuit release | Basic device fixed 15.5 x Iu ± 20% tolerance 496 A, Irm |
| Switching capacity | 25 A (3 contacts in series), DC-5 up to 250V 32 A, AC-3 up to 690 V |
| Assigned motor power at 200/208 V, 60 Hz, 3-phase | 7.5 HP |
| Assigned motor power at 230/240 V, 60 Hz, 1-phase | 5 HP |
| Assigned motor power at 230/240 V, 60 Hz, 3-phase | 10 HP |
| Assigned motor power at 460/480 V, 60 Hz, 3-phase | 20 HP |
| Assigned motor power at 575/600 V, 60 Hz, 3-phase | 25 HP |
| Overload release current setting - min | 25 A |
| Overload release current setting - max | 32 A |
| Tripping characteristic | Overload trigger: tripping class 10 A |
| Equipment heat dissipation, current-dependent Pvid | 9.56 W |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 3.19 W |
| Rated operational current for specified heat dissipation (In) | 32 A |
| Static heat dissipation, non-current-dependent Pvs | 0 W |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |