View larger
PKZM0-25-T 278493 Y7-278493 EATON ELECTRIC Motor-protective circuit-breaker, 3p, Ir 20-25A
PKZM0-25-T
278493
Y7-278493
EATON - MOELLER
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers PKZ
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A PKZM0-25-T 278493 Y7-278493 EATON ELECTRIC Motor-protective circuit-breaker, 3p, Ir 20-25A is a specialized circuit breaker designed specifically to protect electric motors from overloads, phase failures, and short circuits in industrial automation setups.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 25 A
- Rated voltage (EF003977): 690 V
- Overload release current setting (EF002336): 20 A
- Adjustment range undelayed short-circuit release (EF007131): 420 A
- Power loss (EF005387): 6.83 W
- Device construction (EF008240): Built-in device fixed built-in technique
- Integrated earth fault protection (EF007296): false
- Type of electrical connection of main circuit (EF006819): Screw connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): true
- DIN rail (top hat rail) mounting optional (EF008904): true
- With switched-off indicator (EF007006): true
- With integrated under voltage release (EF001390): false
- Number of poles (EF001391): 3
- Type of control element (EF006976): Turn button
- Complete device with protection unit (EF008906): true
- Motor drive integrated (EF006697): false
More info
▲General specifications
VDE 0660
Features & Functions
Transformer protection
General
DIN rail (top hat rail) mounting
≤ 0.25 %/K, residual error for T > 40°
-5 - 40 °C to IEC/EN 60947, VDE 0660
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
1 x (1 - 6) mm²
1.7 Nm, Screw terminals, Main cable
Electrical rating
Short-circuit rating
10 kA, 600 V High Fault, CB, SCCR (UL/CSA) with 125 A, 600 V High Fault, CB, SCCR (UL/CSA)
18 kA, 600 V High Fault, Fuse with CL, SCCR (UL/CSA) with 600 A, 600 V High Fault, Fuse with CL, SCCR (UL/CSA)
18 kA, 600 V High Fault, CB with CL, SCCR (UL/CSA) with 600 A, 600 V High Fault, CB with CL, SCCR (UL/CSA)
18 kA, 480 V High Fault, CB, SCCR (UL/CSA) with 600 A, 480 V High Fault, CB, SCCR (UL/CSA)
18 kA, 480 V High Fault, Fuse, SCCR (UL/CSA) with 600 A, 480 V High Fault, Fuse, SCCR (UL/CSA)
Basic device, fixed 20 x Iu, Trip Blocks
437 A, Irm, Setting range max.