View larger
PKZM0-16 046938 Y7-46938 EATON ELECTRIC Motor-protective circuit-breaker, 3p, Ir 10-16A, screw connection
PKZM0-16
046938
Y7-46938
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers PKZ
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Motor-protective circuit-breaker, 3p, Ir 10-16A, screw connection PKZM0-16 by Eaton Moeller is widely utilized for safeguarding three-phase electric motors against overcurrents.
These thermomagnetic switches disconnect power automatically during thermal overloads or short circuits, ensuring continuous industrial process reliability. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 10 A
- Adjustment range undelayed short-circuit release (EF007131): 248 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): Yes
- Switch off technique (EF007007): Thermomagnetic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 16 A
- Rated operation power at AC-3, 230 V (EF007025): 4 kW
- Rated operation power at AC-3, 400 V (EF001364): 7.5 kW
- Power loss (EF005387): 6.43 W
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rotating button
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
More info
▲General specifications
UL
VDE 0660
UL 60947-4-1
UL Category Control No.: NLRV
CE
CSA-C22.2 No. 60947-4-1-14
IEC/EN 60947
CSA Class No.: 3211-05
UL File No.: E36332
CSA File No.: 165628
CSA
Features & Functions
Motor protection
General
Ex II (2) G [Ex eb Gb] [Ex db Gb] [Ex pxb Gb]
Ex II (2) D [Ex tb Db] [Ex pxb Db]
Also motors with efficiency class IE3
-5 - 40 °C to IEC/EN 60947, VDE 0660
≤ 0.25 %/K, residual error for T > 40°
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
2 x (1 - 6) mm²
1 Nm, Screw terminals, Control circuit cables
Electrical rating
Short-circuit rating
10 kA, 600 V High Fault, CB, SCCR (UL/CSA) with 125 A, 600 V High Fault, CB, SCCR (UL/CSA)
50 kA, 600 V High Fault, CB with CL, SCCR (UL/CSA) with 600 A, 600 V High Fault, CB with CL, SCCR (UL/CSA)
50 kA, 600 V High Fault, Fuse with CL, SCCR (UL/CSA) with 600 A, 600 V High Fault, Fuse with CL, SCCR (UL/CSA)
18 kA, 480 V High Fault, CB, SCCR (UL/CSA) with 600 A, 480 V High Fault, CB, SCCR (UL/CSA)
18 kA, 480 V High Fault, Fuse, SCCR (UL/CSA) with 600 A, 480 V High Fault, Fuse, SCCR (UL/CSA)
42 kA, 240 V, SCCR (UL/CSA)
42 kA, 480 Y/277 V, SCCR (UL/CSA)
Basic device fixed 15.5 x Iu, Trip Blocks
248 A, Irm, Setting range max.