View larger
PKZM01-16 283390 Y7-283390 EATON ELECTRIC Motor-protective circuit-breaker, 3p, Ir 10-16A
PKZM01-16
283390
Y7-283390
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers PKZ
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Motor-protective circuit-breaker, 3p, Ir 10-16A from Eaton Moeller, part number PKZM01-16, provides robust thermomagnetic protection and manual switching for industrial motor applications. These protective devices are standard in control panels to isolate power and prevent motor burnouts caused by electrical faults.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 10 A
- Adjustment range undelayed short-circuit release (EF007131): 248 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): Yes
- Switch off technique (EF007007): Thermomagnetic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 16 A
- Rated operation power at AC-3, 230 V (EF007025): 4 kW
- Rated operation power at AC-3, 400 V (EF001364): 7.5 kW
- Power loss (EF005387): 6.43 W
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Push button
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
More info
▲General specifications
CSA
VDE 0660
CSA Class No.: 3211-05
IEC/EN 60947-4-1
CSA File No.: 165628
IEC/EN 60947
UL File No.: E36332
CE
UL Category Control No.: NLRV
CSA-C22.2 No. 60947-4-1-14
UL
Features & Functions
Phase failure sensitive
General
Also motors with efficiency class IE3
-5 - 40 °C to IEC/EN 60947, VDE 0660
≤ 0.25 %/K, residual error for T > 40°
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
1 x (1 - 6) mm²
Electrical rating
Short-circuit rating
10 kA, 600 V High Fault, CB, SCCR (UL/CSA) with 125 A, 600 V High Fault, CB, SCCR (UL/CSA)
50 kA, 600 V High Fault, CB with CL, SCCR (UL/CSA) with 600 A, 600 V High Fault, CB with CL, SCCR (UL/CSA)
50 kA, 600 V High Fault, Fuse with CL, SCCR (UL/CSA) with 600 A, 600 V High Fault, Fuse with CL, SCCR (UL/CSA)
18 kA, 480 V High Fault, CB, SCCR (UL/CSA) with 600 A, 480 V High Fault, CB, SCCR (UL/CSA)
18 kA, 480 V High Fault, Fuse, SCCR (UL/CSA) with 600 A, 480 V High Fault, Fuse, SCCR (UL/CSA)
± 20% tolerance, Trip blocks
Basic device fixed 15.5 x Iu, Trip Blocks