PKE12/XTU-4 121732 Y7-121732 EATON ELECTRIC Motor-protective circuit-breaker, 3p, Ir 1-4A, standard
PKE12/XTU-4
121732
Y7-121732
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Electronic Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller motor-protective circuit-breaker (PKE12/XTU-4) provides reliable fault interruption and thermal-magnetic protection for industrial electric motors. Circuit breakers of this type are widely deployed within electrical control cabinets to prevent damage from overloads, phase failures, and short circuits during standard operational cycles. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 1 A
- Adjustment range undelayed short-circuit release (EF007131): 62 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): Yes
- Switch off technique (EF007007): Electronic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 4 A
- Rated operation power at AC-3, 230 V (EF007025): 0.75 kW
- Rated operation power at AC-3, 400 V (EF001364): 1.5 kW
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rotating button
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
UL 508
EN 60947-4-1
IEC 60947-4-1
VDE
CSA-C22.2 No. 60947-4-1-14
IEC/EN 60947-4-1
IEC/EN 60947
CSA Class No.: 3211-05
UL 60947-4-1
CSA
CSA File No.: 165628
UL
UL Category Control No.: NLRV
UL File No.: E36332
VDE 0660
CE
Features & Functions
Phase failure sensitive
Overload release
Motor protection
General
Note: Going below the minimum current flow time can cause overheating of the load (motor).
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods.
900 (Class 15) AC-4 cycle operation, Main conducting paths
1000 (Class 20) AC-4 cycle operation, Main conducting paths
700 (Class 10) AC-4 cycle operation, Main conducting paths
IP20
-5 - 40 °C to IEC/EN 60947, VDE 0660
Ambient conditions, mechanical
Climatic environmental conditions
Damp heat, cyclic, to IEC 60068-2-30
Terminal capacities
2 x (1 - 6) mm², ferrule to DIN 46228
2 x (1 - 6) mm²
1.7 Nm, Screw terminals, Main cable
Electrical rating
Short-circuit rating
100 kA, 600 V High Fault, Fuse, SCCR (UL/CSA)
Trip block fixed 15.5 x Ir
Delayed approx. 60 ms, Trip blocks
Basic device fixed 15.5 x Iu, Trip Blocks