View larger
PKZM0-0,4 072732 Y7-72732 EATON ELECTRIC Motor-protective circuit-breaker, 3p, Ir 0.25-0.4A, screw connection
PKZM0-0,4
072732
Y7-72732
EATON - MOELLER
1 Pcs.
Automation > Motor protection circuit-breaker
Circuit Breakers PKZ
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller part number PKZM0-0,4 is a 3-pole motor-protective circuit-breaker engineered for precise thermomagnetic current control in low-power electrical drives. Industrial control systems rely on these compact units to prevent motor failure due to overloads or locked rotor conditions. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Overload release current setting (EF002336): 0.25 A
- Adjustment range undelayed short-circuit release (EF007131): 6.2 A
- With thermal overload protection (EF006233): No
- Phase failure sensitive (EF007400): Yes
- Switch off technique (EF007007): Thermomagnetic
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 0.4 A
- Rated operation power at AC-3, 230 V (EF007025): 0.06 kW
- Rated operation power at AC-3, 400 V (EF001364): 0.09 kW
- Power loss (EF005387): 5.22 W
- Type of electrical connection of main circuit (EF006819): Screw connection
- Type of control element (EF006976): Rotating button
- Device construction (EF008240): Built-in device fixed built-in technique
- With integrated auxiliary switch (EF001387): No
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
More info
▲General specifications
IEC/EN 60947
CSA
UL
CSA Class No.: 3211-05
IEC/EN 60947-4-1
UL File No.: E36332
CSA File No.: 165628
VDE 0660
CSA-C22.2 No. 60947-4-1-14
UL 60947-4-1
UL Category Control No.: NLRV
Features & Functions
Motor protection
General
Branch circuit: Manual type E if used with terminal, or suitable for group installations, (UL/CSA)
-5 - 40 °C to IEC/EN 60947, VDE 0660
-25 - 55 °C, Operating range
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-78
Terminal capacities
1 x (1 - 6) mm², ferrule to DIN 46228
1 x (1 - 6) mm²
1 Nm, Screw terminals, Control circuit cables
Electrical rating
Short-circuit rating
50 kA, 600 V High Fault, CB, SCCR (UL/CSA) with 600 A, 600 V High Fault, CB, SCCR (UL/CSA)
65 kA, 240 V, SCCR (UL/CSA)
Accessories required BK25/3-PKZ0-E
65 kA, 480 Y/277 V, SCCR (UL/CSA)
± 20% tolerance, Trip blocks
Basic device fixed 15.5 x Iu, Trip Blocks