View larger
MSC-DEA-1,2-M7(24VDC) 121753 Y7-121753 EATON ELECTRIC DOL starter, 3p, 0.06-0.37kW/400V/AC3, 100kA, protecti..
MSC-DEA-1,2-M7(24VDC)
121753
Y7-121753
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Electronic Circuit Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller DOL starter, specifically part number MSC-DEA-1,2-M7(24VDC), is an integrated electromechanical assembly used to safely switch and protect three-phase electric motors directly across the line. Devices of this type provide centralized switching, short-circuit protection, and adjustable thermal-magnetic overload monitoring within industrial control panels.
Exact pricing, availability, and lead times are confirmed per enquiry through our formal RFQ process.
- Type of motor starter (EF009598): Direct starter
- With short-circuit release (EF006691): Yes
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Rated operation power at AC-3, 230 V, 3-phase (EF009599): 0.18 kW
- Rated operation power at AC-3, 400 V (EF001364): 0.37 kW
- Rated power, 460 V, 60 Hz, 3-phase (EF009600): 0 kW
- Rated power, 575 V, 60 Hz, 3-phase (EF009601): 0 kW
- Rated operation current Ie (EF001443): 1.1 A
- Rated operation current at AC-3, 400 V (EF009602): 1.2 A
- Overload release current setting (EF002336): 0.3 A
- Ambient temperature, upper operating limit (EF009603): 55 °C
- Temperature compensated overload protection (EF009604): Yes
- Release class (EF006668): Adjustable
More info
▲Delivery program
IE3-ready devices are identified by the logo on their packaging.
in conjunction with PKE-SWD-32 SmartWire DT PKE module
Mechanical connection element and electrical electric contact module
The DOL starters (complete units) consist of a PKE motor protective circuit breaker and a DILM contactor.
With the adapter-less top-hat rail mounting of starters up to 15 A, only the motor protective circuit breaker on the top-hat rail requires an adapter.
The contactors are provided with mechanical support via a mechanical connection element.
Control wire guide with max. 6 conductors up to 2.5 mm external diameter or 4 conductors up to 3.5 mm external diameter.
The connection of the main circuit between PKE and contactor is established with electrical contact modules.
When using DILA-XHIT… auxiliary contacts with MSC-DE-... DOL starters, the plug-in electrical connectors can be removed without removing the front-mounted auxiliary contact.
Cannot be combined with NHI‐E…PKZ0‐C.
The MSC-DEA... DOL starters are prepared for communication via SmartWire-DT. For this, the PKE-SWD-32 communication module must be added.
Motor rating | Rated motor current | |||||
|---|---|---|---|---|---|---|
AC-3 | ||||||
| 220 V 230 V 240 V | 380 V 400 V | 415 V | ||||
| Iq= 100 kA | Iq=100 kA | Iq= 50 kA | ||||
| P | I | I | I | |||
| kW | A | A | A | |||
| 0.06 | 0.37 | - | - | |||
| 0.09 | 0.54 | 0.31 | 0.31 | |||
| 0.12 | 0.72 | 0.41 | 0.41 | |||
| 0.18 | 1.04 | 0.6 | 0.6 | |||
| 0.25 | - | 0.8 | 0.8 | |||
| 0.37 | - | 1.1 | 1.1 |
Technical data
700 (Class 10)
900 (Class 15)
1000 (Class 20) ms
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods. ms
DILM contactors, see contactor product group