View larger
PLS6-C16/4-MW 243087 Y7-243087 EATON ELECTRIC Over current switch, 16A, 4 p, type C characteristic
PLS6-C16/4-MW
243087
Y7-243087
EATON - MOELLER
1 Pcs.
Automation > Miniature circuit breaker (MCB)
Modular Switchgear – Big Home
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Over current switch, 16A, 4 p, type C characteristic cataloged as PLS6-C16/4-MW 243087 Y7-243087 by Eaton Moeller is a four-pole modular breaker built for reliable electrical protection in commercial buildings and industrial control panels. It isolates power during fault conditions to prevent electrical hazards.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Name: Eaton Moeller series xPole - PLS6/M MCB
- Catalog Number: 243087
- Model Code: PLS6-C16/4-MW
- EAN: 4015082430870
- Product Length/Depth: 85 mm
- Product Height: 73 mm
- Product Width: 70 mm
- Product Weight: 0.48 kg
- Compliances: RoHS conform
- Number of poles: Four-pole
- Number of poles (total): 4
- Number of poles (protected): 4
- Tripping characteristic: C
- Release characteristic: C
- Amperage Rating: 16 A
- Type: Miniature circuit breaker PLS6
More info
▲General specifications
| Product Name | Eaton Moeller series xPole - PLS6/M MCB |
| Catalog Number | 243087 |
| Model Code | PLS6-C16/4-MW |
| EAN | 4015082430870 |
| Product Length/Depth | 85 mm |
| Product Height | 73 mm |
| Product Width | 70 mm |
| Product Weight | 0.48 kg |
| Compliances | RoHS conform |
Delivery program
| Application |
|
| Number of poles | Four-pole |
| Number of poles (total) | 4 |
| Number of poles (protected) | 4 |
| Tripping characteristic | C |
| Release characteristic | C |
| Amperage Rating | 16 A |
| Type |
|
Technical Data - Electrical
| Voltage type | AC |
| Rated operational voltage (Ue) - max | 400 V |
| Rated insulation voltage (Ui) | 440 V |
| Rated impulse withstand voltage (Uimp) | 4 kV |
| Frequency rating - min | 50 Hz |
| Frequency rating - max | 60 Hz |
| Rated switching capacity (IEC/EN 60898-1) | 6 kA |
| Overvoltage category | III |
| Pollution degree | 2 |
Technical Data - Mechanical
| Width in number of modular spacings | 4 |
| Built-in depth | 70.5 mm |
| Degree of protection | IP20 |
| Connectable conductor cross section (solid-core) - min | 1 mm² |
| Connectable conductor cross section (solid-core) - max | 25 mm² |
| Connectable conductor cross section (multi-wired) - min | 1 mm² |
| Connectable conductor cross section (multi-wired) - max | 25 mm² |
Design verification as per IEC/EN 61439 - technical data
| Rated operational current for specified heat dissipation (In) | 16 A |
| Heat dissipation per pole, current-dependent | 0 W |
| Equipment heat dissipation, current-dependent | 8.8 W |
| Static heat dissipation, non-current-dependent | 0 W |
| Heat dissipation capacity | 0 W |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature - max | 75 °C |
Design verification as per IEC/EN 61439
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Additional information
| Current limiting class | 3 |
| Features | Additional equipment possible Concurrently switching N-neutral |
| Special features | Ambient temperature hint: a 1 °C increase results in a 0.5% linear reduction of current carrying capacity |
| Used with | Miniature circuit breaker PLS6 |