EATON - MOELLER 3.6KV 40A 2.5" OIL FUSE 3.6KV 40A 2.5" OIL FUSE 3.6OEFMA40 3-6OEFMA40 EATON ELECTRIC VT fuse-link, medium voltage, 3 A, AC 15.5 kV, .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

3.6KV 40A 2.5" OIL FUSE 3.6OEFMA40 3-6OEFMA40 EATON ELECTRIC VT fuse-link, medium voltage, 3 A, AC 15.5 kV, ..

3.6KV 40A 2.5" OIL FUSE

3.6OEFMA40

3-6OEFMA40

EATON - MOELLER

3 Pcs.

VT fuse-link, medium voltage, 3 A, AC 15.5 kV, 254 x 25.4 mm, back-up, BS, IEC, style 22 tags, oil tight 3.6KV 40AMP 2.5" OIL FUSE 3.6KV 40AMP 2.5" OIL FUSE - Oil fuse-link, medium voltage, 40 A, AC 3.6 kV, 50 kA, BS2692 F01, 254 x 63.5 mm, back-up, BS, IEC, ESI, with striker, oil-tight Fuse, Oil fuse-link, medium voltage, 40 A, AC 3.6 kV, BS2692 F01, 254 x 63.5 mm, back-up, BS, IEC, ESI, with striker, cylindrical, oil-tight, protection of primary side transformer, and oil-filled fuse switch combination unit, BS2692-1, IEC 60282-1, ESI 12-8, Breaking Capacity 50 kA

Automation > Medium-/high voltage fuse
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Oil fuse-link, medium voltage, 40 A, AC 3.6 kV, 50 kA, BS2692 F01, 254 x 63.5 mm, back-up, BS, IEC, ESI, with striker, oil-tight
Fuse, Oil fuse-link, medium voltage, 40 A, AC 3.6 kV, BS2692 F01, 254 x 63.5 mm, back-up, BS, IEC, ESI, with striker, cylindrical, oil-tight, protection of primary side transformer, and oil-filled fuse switch combination unit, BS2692-1, IEC 60282-1, ESI 12-8, Breaking Capacity 50 kA

Delivery program

Product range
Fuse
Basic function
Oil fuse-link
Field of application
medium voltage
Rated current [I]
40 A
Rated voltage
AC 3.6 kV
Construction size
BS2692 F01
Size
254 x 63.5 mm
Utilization category
back-up
Status indicator
with striker
Description
oil-tight
Breaking Capacity
50 kA
usable for size/applications
protection of primary side transformer, and oil-filled fuse switch combination unit
Standard/Approval
BS
IEC
ESI
Shape
cylindrical
Standards/Regulations
BS2692-1
IEC 60282-1
ESI 12-8

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Medium-/high voltage fuse (EC003507)
Rated current
40 A
Rated voltage
3.6 kV
Voltage type
AC
Rated frequency
50 - 50 Hz
Breaking capacity
50 kA
Utilization category
Other
Application
Primary side transformer protection
Length
254 mm
Diameter
63.5 mm
Performance category according to IEC 60282-1
Back-up
With striker
Yes
Standard
British Standard
Release characteristic
Other
Installation technique
Oil

ETIM for 3.6OEFMA40 Circuit breakers and fuses (EC003507)
Feature Name Feature Value
Rated current (EF000227) 40 A
Rated voltage (EF000228) 3.6 kV
Voltage type (EF000187) AC
Rated frequency (EF001663) 50 Hz
Breaking capacity (EF005617) 50 kA
Utilization category according to IEC 60269 (EF002572) Other
Application (EF000041) Primary side transformer protection
Length (EF001438) 254 mm
Diameter (EF000551) 63.5 mm
Performance category according to IEC 60282-1 (EF012539) Back-up
With striker (EF008175) Yes
Standard (EF009322) British Standard
Release characteristic (EF000889) Other
Installation technique (EF001474) Oil

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.