Motor fuse-link, medium voltage, 63 A, AC 3.6 kV, 51 x 254 mm, back-up, BS, with striker, no tags 8.25KV 125E RATING TWIN 3" FUSE - Fuse-link, medium voltage, 125 A, AC 8.25 kV, 76 x 254 mm, full-range, ANSI, 125E Fuse, Fuse-link, medium voltage, 125 A, AC 8.25 kV, 76 x 254 mm, full-range, ANSI, 125E, cylindrical, type E, Special tag, protection of primary side transformers, BS2692-1, Breaking Capacity 50 kA

Automation > Medium-/high voltage fuse
Bussmann fuses

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Fuse-link, medium voltage, 125 A, AC 8.25 kV, 76 x 254 mm, full-range, ANSI, 125E
Fuse, Fuse-link, medium voltage, 125 A, AC 8.25 kV, 76 x 254 mm, full-range, ANSI, 125E, cylindrical, type E, Special tag, protection of primary side transformers, BS2692-1, Breaking Capacity 50 kA

Delivery program

Product range
Fuse
Basic function
Fuse-link
Field of application
medium voltage
Rated current [I]
125 A
Rated voltage
AC 8.25 kV
Size
76 x 254 mm
Utilization category
full-range
Description
type E
Special tag
Breaking Capacity
50 kA
usable for size/applications
protection of primary side transformers
Release characteristic [class]
125E
Standard/Approval
ANSI
Shape
cylindrical
Standards/Regulations
BS2692-1

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Medium-/high voltage fuse (EC003507)
Rated current
125 A
Rated voltage
8.25 kV
Voltage type
AC
Rated frequency
60 - 60 Hz
Breaking capacity
50 kA
Utilization category
Other
Application
Primary side transformer protection
Length
254 mm
Diameter
76 mm
Performance category according to IEC 60282-1
Full-range
With striker
Yes
Standard
ANSI
Release characteristic
E
Installation technique
Air

ETIM for 8.25FFNHK125E Circuit breakers and fuses (EC003507)
Feature Name Feature Value
Rated current (EF000227) 125 A
Voltage type (EF000187) AC
Breaking capacity (EF005617) 0.05 kA
Utilization category according to IEC 60269 (EF002572) Other
Length (EF001438) 254 mm
Performance category according to IEC 60282-1 (EF012539) Full range
With striker (EF008175) Yes
Standard (EF009322) ANSI
Release characteristic (EF000889) E
Installation technique (EF001474) Air

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.