EATON - MOELLER 7.2KV 50Amp 2" 'B' Air Fuse 7.2KV 50Amp 2" 'B' Air Fuse 7.2ADFHB50 7-2ADFHB50 EATON ELECTRIC Air fuse-link, medium voltage, 3 A, AC 11.5.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

7.2KV 50Amp 2" 'B' Air Fuse 7.2ADFHB50 7-2ADFHB50 EATON ELECTRIC Air fuse-link, medium voltage, 3 A, AC 11.5..

7.2KV 50Amp 2" 'B' Air Fuse

7.2ADFHB50

7-2ADFHB50

EATON - MOELLER

3 Pcs.

Air fuse-link, medium voltage, 3 A, AC 11.5 kV, 425 x 76.2 mm, back-up, BS, no striker 7.2KV 50Amp 2" 'B' Air Fuse 7.2KV 50Amp 2" 'B' Air Fuse - Air fuse-link, medium voltage, 50 A, AC 7.2 kV Air fuse-link, medium voltage, 50 A, AC 7.2 kV, 336 x 50.8 mm, back-up, BS, with striker, style B tags

Automation > Medium-/high voltage fuse
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A medium-voltage air fuse link engineered for primary transformer protection in electrical power distribution infrastructure. The Eaton Moeller device safely interrupts fault currents in high-voltage industrial circuits.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Rated current: 50 A
  • Rated voltage: 7.2 kV
  • Voltage type: AC
  • Rated frequency: 50 Hz
  • Breaking capacity: 20 kA
  • Application: Primary side transformer protection
  • Length: 254 mm
  • Diameter: 51 mm
  • Performance category according to IEC 60282-1: Back-up
  • With striker: Yes
  • Standard: British Standard
  • Installation technique: Air

More info

▲
Air fuse-link, medium voltage, 50 A, AC 7.2 kV
Fuse, Air fuse-link, medium voltage, 50 A, AC 7.2 kV, 51 x 254 mm, back-up, BS, with striker, cylindrical with offset tag single bolt fixing, protection of primary side transformers, used in fuse switch combination units, fuse bases and fuse switches, BS2692-1, Breaking Capacity 20 kA

Delivery program

Product range
Fuse
Basic function
Air fuse-link
Field of application
medium voltage
Rated current [I]
50 A
Rated voltage
AC 7.2 kV

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Medium-/high voltage fuse (EC003507)
Rated current
50 A
Rated voltage
7.2 kV
Voltage type
AC
Rated frequency
50 - 50 Hz
Breaking capacity
20 kA
Utilization category
Other
Application
Primary side transformer protection
Length
254 mm
Diameter
51 mm
Performance category according to IEC 60282-1
Back-up
With striker
Yes
Standard
British Standard
Release characteristic
Other
Installation technique
Air

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.