EATON - MOELLER 7.2KV 50Amp 2" 'B' Air Fuse 7.2KV 50Amp 2" 'B' Air Fuse 7.2ADFHB50 7-2ADFHB50 EATON ELECTRIC Air fuse-link, medium voltage, 3 A, AC 11.5.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

7.2KV 50Amp 2" 'B' Air Fuse 7.2ADFHB50 7-2ADFHB50 EATON ELECTRIC Air fuse-link, medium voltage, 3 A, AC 11.5..

7.2KV 50Amp 2" 'B' Air Fuse

7.2ADFHB50

7-2ADFHB50

EATON - MOELLER

3 Pcs.

Air fuse-link, medium voltage, 3 A, AC 11.5 kV, 425 x 76.2 mm, back-up, BS, no striker 7.2KV 50Amp 2" 'B' Air Fuse 7.2KV 50Amp 2" 'B' Air Fuse - Air fuse-link, medium voltage, 50 A, AC 7.2 kV Air fuse-link, medium voltage, 50 A, AC 7.2 kV, 336 x 50.8 mm, back-up, BS, with striker, style B tags

Automation > Medium-/high voltage fuse
Bussmann Series Medium Voltage fuses and accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Air fuse-link, medium voltage, 50 A, AC 7.2 kV
Fuse, Air fuse-link, medium voltage, 50 A, AC 7.2 kV, 51 x 254 mm, back-up, BS, with striker, cylindrical with offset tag single bolt fixing, protection of primary side transformers, used in fuse switch combination units, fuse bases and fuse switches, BS2692-1, Breaking Capacity 20 kA

Delivery program

Product range
Fuse
Basic function
Air fuse-link
Field of application
medium voltage
Rated current [I]
50 A
Rated voltage
AC 7.2 kV

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Medium-/high voltage fuse (EC003507)
Rated current
50 A
Rated voltage
7.2 kV
Voltage type
AC
Rated frequency
50 - 50 Hz
Breaking capacity
20 kA
Utilization category
Other
Application
Primary side transformer protection
Length
254 mm
Diameter
51 mm
Performance category according to IEC 60282-1
Back-up
With striker
Yes
Standard
British Standard
Release characteristic
Other
Installation technique
Air

ETIM for 7.2ADFHB50 Circuit breakers and fuses (EC003507)
Feature Name Feature Value
Rated current (EF000227) 50 A
Rated voltage (EF000228) 7.2 kV
Voltage type (EF000187) AC
Rated frequency (EF001663) 50 Hz
Breaking capacity (EF005617) 20 kA
Utilization category according to IEC 60269 (EF002572) Other
Application (EF000041) Primary side transformer protection
Length (EF001438) 254 mm
Diameter (EF000551) 51 mm
Performance category according to IEC 60282-1 (EF012539) Back-up
With striker (EF008175) Yes
Standard (EF009322) British Standard
Release characteristic (EF000889) Other
Installation technique (EF001474) Air

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.