EATON - MOELLER T6-160-6/I45/SVB/HI11 T6-160-6/I45/SVB/HI11 201448 Y7-201448 EATON ELECTRIC Main switch, 6 pole + 1 N/O + 1 N/C, 160 A, Emergency-.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

T6-160-6/I45/SVB/HI11 201448 Y7-201448 EATON ELECTRIC Main switch, 6 pole + 1 N/O + 1 N/C, 160 A, Emergency-..

T6-160-6/I45/SVB/HI11

201448

Y7-201448

EATON - MOELLER

1 Pcs.

Main switch, 6 pole + 1 N/O + 1 N/C, 160 A, Emergency-Stop function, 90 °, Lockable in the 0 (Off) position, surface mounting T6-160-6/I45/SVB/HI11 Eaton Moeller® series T6 Main switch, T6, 160 A, surface mounting, 6 contact unit(s), 6 pole, 1 N/O, 1 N/C, Emergency switching off function, With red rotary handle and yellow locking ring, Lockable in the 0 (Off) position Main switch, Product range: Main switch, maintenance switch, Repair switch, Part group reference: T6, Stop Function: Emergency switching off function, With red rotary handle and yellow locking ring, Information about equipment supplied: Enclosure without flanges with K95/1N/BR., FL4 gland plate insert... order separately, see CI insulated enclosure -> accessories, 6 pole, Locking facility: Lockable in the 0 (Off) position, Degree of Protection: IP65, Design: surface mounting, Switching angle: 90 °, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 55 kW, Rated uninterrupted current: Iu = 160 A, 6 contact unit(s), Standards: IEC/EN 60947, VDE 0660 , IEC/EN 60204, Switch-disconnector according to IEC/EN 60947-3

Connectors > Switch disconnector
Disconnectors and Cam Switches

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Operating as a primary safety isolation device, the Eaton Moeller T6-160-6/I45/SVB/HI11 (201448) main switch is designed to disconnect entire machinery systems from power sources to ensure technician safety during maintenance. Such multi-pole safety switches combine emergency-stop functionality and auxiliary contacts for comprehensive industrial control integration.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Version as main switch (EF006981): Yes
  • Version as maintenance-/service switch (EF006986): Yes
  • Version as safety switch (EF006985): No
  • Version as emergency stop installation (EF006959): No
  • Version as reversing switch (EF009408): No
  • Number of switches (EF005586): 1
  • Rated operating voltage (EF001435): 690 V
  • Rated permanent current Iu (EF001389): 160 A
  • Rated permanent current at AC-23, 400 V (EF011777): 105 A
  • Rated permanent current at AC-21, 400 V (EF009165): 160 A
  • Rated operation power at AC-3, 400 V (EF001364): 45 kW
  • Rated short-time withstand current lcw (EF007050): 3 kA
  • Rated operation power at AC-23, 400 V (EF007027): 55 kW
  • Switching power at 400 V (EF009166): 55 kW
  • Conditioned rated short-circuit current Iq (EF001444): 5 kA
  • Number of poles (EF001391): 6

More info

▲

General specifications

Product Name
Eaton Moeller® series T6 Main switch
Catalog Number
201448
Model Code
T6-160-6/I45/SVB/HI11
EAN
4015082014483
Product Length/Depth
500 mm
Product Height
285 mm
Product Width
375 mm
Product Weight
5.4 kg
Certifications
IEC 60947
EN 60204
EN 60947
VDE
IEC/EN 60947-3
VDE 0660
IEC/EN 60204
IEC/EN 60947
Catalog Notes
Rated Short-time Withstand Current (Icw) for a time of 1 second

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.