EATON - MOELLER T3-2-8324/V/SVB-SW T3-2-8324/V/SVB-SW 008775 Y7-8775 EATON ELECTRIC Main switch, 4 pole, 32 A, STOP function, 90 °, rear mounti.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

T3-2-8324/V/SVB-SW 008775 Y7-8775 EATON ELECTRIC Main switch, 4 pole, 32 A, STOP function, 90 °, rear mounti..

T3-2-8324/V/SVB-SW

008775

Y7-8775

EATON - MOELLER

1 Pcs.

Main switch, 4 pole, 32 A, STOP function, 90 °, rear mounting General Switch 4 poles 32 A 90° Bottom panel mount Handle Eaton Moeller® series T3 Main switch, T3, 32 A, rear mounting, 2 contact unit(s), 4 pole, STOP function, With black rotary handle and locking ring Main switch, Product range: Main switch, maintenance switch, Repair switch, Part group reference: T3, Stop Function: STOP function, With black rotary handle and locking ring, 4 pole, Degree of Protection: Front IP65, Design: rear mounting, Switching angle: 90 °, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 15 kW, Rated uninterrupted current: Iu = 32 A, 2 contact unit(s), Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL, Switch-disconnector according to IEC/EN 60947-3

Connectors > Switch disconnector
Disconnectors and Cam Switches

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

T3-2-8324/V/SVB-SW 008775 Y7-8775 EATON ELECTRIC Main switch, 4 pole, 32 A, STOP function, 90 °, rear mounting operates as a rotary control and isolation switch engineered for general industrial power management. Engineers typically mount these units on enclosure panels to serve as reliable main disconnects for smaller machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Version as main switch (EF006981): Yes
  • Version as maintenance-/service switch (EF006986): Yes
  • Version as safety switch (EF006985): No
  • Version as emergency stop installation (EF006959): No
  • Version as reversing switch (EF009408): No
  • Number of switches (EF005586): 1
  • Rated operating voltage (EF001435): 690 V
  • Rated permanent current Iu (EF001389): 32 A
  • Rated permanent current at AC-21, 400 V (EF009165): 32 A
  • Rated operation power at AC-3, 400 V (EF001364): 11 kW
  • Rated short-time withstand current lcw (EF007050): 0.65 kA
  • Rated operation power at AC-23, 400 V (EF007027): 15 kW
  • Switching power at 400 V (EF009166): 15 kW
  • Conditioned rated short-circuit current Iq (EF001444): 1 kA
  • Number of poles (EF001391): 4
  • Motor drive optional (EF007386): No

More info

▲

General specifications

Product Name
Eaton Moeller® series T3 Main switch
Catalog Number
008775
Model Code
T3-2-8324/V/SVB-SW
EAN
4015080087755
Product Length/Depth
133 mm
Product Height
74 mm
Product Width
65 mm
Product Weight
0.23 kg
Certifications
CSA Class No.: 3211-05
CSA-C22.2 No. 60947-4-1-14
UL
UL File No.: E36332
CSA
VDE 0660
CSA-C22.2 No. 94
IEC/EN 60204
IEC/EN 60947
UL Category Control No.: NLRV
IEC/EN 60947-3
CE
UL 60947-4-1
CSA File No.: 012528
Catalog Notes
Rated Short-time Withstand Current (Icw) for a time of 1 second

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.