EATON - MOELLER DX-LN3-004 DX-LN3-004 269500 Y7-269500 EATON ELECTRIC Main choke, AC, 3p, 3.9A, 7.51mH, 550V50/60Hz View larger
Images are for illustrative purposes only. Please refer to data sheet for details

DX-LN3-004 269500 Y7-269500 EATON ELECTRIC Main choke, AC, 3p, 3.9A, 7.51mH, 550V50/60Hz

DX-LN3-004

269500

Y7-269500

EATON - MOELLER

1 Pcs.

Main choke, AC, 3p, 3.9A, 7.51mH, 550V50/60Hz DX-LN3-004 Main choke, three-phase, 550 V + 0% (50/60 Hz), V AC, 3.9 A, 7.51 mH Main choke, rated operating voltage 480 V AC, three-phase, uk =4%

Automation > Coil for low-voltage
Eaton Frequency Converters

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Main choke, three-phase, 550 V + 0% (50/60 Hz), V AC, 3.9 A, 7.51 mH
Main choke, rated operating voltage 480 V AC, three-phase, uk =4%

General specifications
Product name
Eaton DX Mains choke
Part no.
DX-LN3-004
EAN
4015082695002
Product Length/Depth
66 millimetre
Product height
118 millimetre
Product width
115 millimetre
Product weight
1.5 kilogram
Compliances
CE Marked
Certifications
UL 508C
IEC 61800-5
EN 61800-3
CSA Std. C22.2 No. 14
VDE
CE
VDE 0570 Part 2-20/2001-04
Certified by UL for use in Canada
CSA-C22.2 No. 14
CSA
IEC/EN 61558-2-20-2000
UL
UL Category Control No.: XPTQ2, XPTQ8
UL report applies to both US and Canada
IEC/EN61800-5
IEC/EN61800-3
UL File No.: E167225
UL
CSA
Product Tradename
DX
Product Type
Accessory
Product Sub Type
Mains choke
Features & Functions
Fitted with:
Terminations
PE stud
Number of phases
3
Number of poles
Three-pole
General information
Degree of protection
IP20
NEMA Other
Duty factor
100 %
Frequency rating
50-60 Hz
Insulation class
B
Product Category
Accessories
Suitable as
Net reactance coil
Suitable for
Branch circuits, (UL/CSA)
Switching frequency
0 kHz
Used with
DA1
DE1
DC1
SPX
SVX
DA1, DB1, DC1, DE1, DE11, DG1, DM1, SPX, SVX
Ambient conditions, mechanical
Mounting position
Free surrounding areas > 50 mm
Standing vertically
Suspended horizontally
Shock resistance
3 shocks
Shock duration: 11 ms
Vibration resistance
0 - 150 Hz, 1 g
10 - 55 Hz, 0.35 mm
Climatic environmental conditions
Altitude
Max. 1000 m
Max. 5000 m with current reduction
Ambient operating temperature - max
40 °C
Ambient operating temperature - min
-25 °C
Ambient storage temperature - max
85 °C
Ambient storage temperature - min
-25 °C
Operating temperature details
-25 - 40 °C (up to 70 °C with current derating)
Terminal capacities
Terminal capacity
20 - 10 AWG
4 mm²
Tightening torque
0.8 Nm, Screw terminals
Electrical rating
Permissible connection voltage
Max. 550 V AC (50/60 Hz)
Rated current (Ith) at rated voltage DC - max
3.9 A
Rated frequency - min
50 Hz
Rated frequency - max
60 Hz
Rated inductance
7.51 mH
Rated operational current (Ie) - min
3.9 A
Rated operational current (Ie) - max
3.9 A
Rated operational voltage (Ue) - max
550 V
Relative short-circuit voltage
4 %
Voltage rating - max
480 V
Voltage sag Uk
4 %
Design verification
Heat dissipation capacity Pdiss
0 W
Rated operational current for specified heat dissipation (In)
3.9 A
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 9.0

Low-voltage industrial components (EG000017) / Coil for low-voltage (EC002563)
Electric engineering, automation, process control engineering / Electronic coil and filter / Electronic choke coil / Electronic choke coil (unspecified) (ecl@ss13-27-42-01-90 [ADJ199012])
Suitable as interference suppression reactance coil
No
Suitable as net reactance coil
Yes
Suitable as commutation reactance coil
No
Suitable as ripple filter choke
No
Suitable as output reactance coil
No
Number of poles, primary side
3
Rated clock frequency
0 kHz
Rated operating frequency
50 - 60 Hz
Max. rated operation voltage Ue
550 V
Rated current AC
3.9 - 3.9 A
Max. rated current (Ith) at rated voltage DC
3.9 A
Rated inductance
7.51 mH
Degree of protection (IP)
IP20
Relative short circuit voltage
4 %
Resonance frequency
0 Hz
Degree of protection (NEMA)
Other

ETIM for 269500 Low-voltage industrial controls and switchgear (EC002563)
Feature Name Feature Value
Suitable as interference suppression reactance coil (EF007230) No
Suitable as net reactance coil (EF007234) Yes
Suitable as commutation reactance coil (EF007233) No
Suitable as ripple filter choke (EF007232) No
Suitable as output reactance coil (EF007227) No
Number of poles, primary side (EF007403) 3
Rated clock frequency (EF007502) 0 kHz
Rated operating frequency (EF007024) 50 Hz
Max. rated operation voltage Ue (EF007357) 550 V
Rated current AC (EF007500) 3.9 A
Max. rated current (Ith) at rated voltage DC (EF007359) 3.9 A
Rated inductance (EF007291) 7.51 mH
Degree of protection (IP) (EF005474) IP20
Relative short circuit voltage (EF007452) 4 %
Resonance frequency (EF007455) 0 Hz
Degree of protection (NEMA) (EF011959) Other

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.