EATON - MOELLER LTS-100/C00/3-R LTS-100/C00/3-R 284690 EATON ELECTRIC NH fuse switch-disconnector, 125A, 500V, size 000, width 63 mm View larger
Images are for illustrative purposes only. Please refer to data sheet for details

LTS-100/C00/3-R 284690 EATON ELECTRIC NH fuse switch-disconnector, 125A, 500V, size 000, width 63 mm

LTS-100/C00/3-R

284690

EATON - MOELLER

1 Pcs.

NH fuse switch-disconnector, 125A, 500V, size 000, width 63 mm Base for fuses NH000 NH fuse switch-disconnector, 125 A, 500V, Size 000, width 63 mm, supplied without NH fuse-links, cable outlet at the bottom, ideal for use in service distribution boards conforming to EN 61439-2 due to space-saving width of only 63 mm.

Connectors > Fuse switch disconnector
Industrial Fuse Bases

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

NH fuse switch-disconnector, 125A, 500V, size 000, width 63 mm
NH fuse switch-disconnector, 125 A, 500V, Size 000, width 63 mm, supplied without NH fuse-links, cable outlet at the bottom, ideal for use in service distribution boards conforming to EN 61439-2 due to space-saving width of only 63 mm.

Delivery program

Product range
60 mm system
Subrange
NH fuse switch-disconnectors
Description
Including handguard at top and bottom
Mounting without holes
Function
For surface mounting on busbars
Number of poles
3 pole
Connection
Box terminal 1.5…50 mm2
Bottom
Interval between busbar centres
60 mm
Max. fuse
500 V
125 A
Frame size
NH000
For use with
20 x 5/10
30 x 5/10
For use with
Double T profile

Technical data

General
Standards
IEC/EN 60947-3
Ambient temperature
-25 - +55
Altitude
Max. 2000 m
Interval between busbar centres
60 mm
Mounting position
Vertical or horizontal
Overvoltage category/pollution degree
III/3
Protection type
IP20 (Operating state)
IP10 (Front cover open)
Degree of protection, from the frontOperational state
IP20
Degree of protection, from the frontFront cover open
IP10
Direction of incoming supply
as required
Lifespan, mechanical [Operations]
1400
Weight
0.57 kg
Contacts
Rated operational voltage [Ue]
500 V AC
Rated operational current [Ie]
125 A
Rated frequency [f]
40 - 60 Hz
Rated conditional short-circuit current AC [Iq]
50 kAeff
Utilization category AC­22BRated making capacity
300 A
Utilization category AC­22BRated breaking capacity
300 A
Lifespan, electrical [Operations]
200
Electrical
≧ 200 Operations
Lifespan, mechanical [Operations]
1400
Heat dissipation at IthAC, without NH-SE
18 W
Rated insulation voltage [Ui]
500 V AC
Rated impulse withstand voltage [Uimp]
8 kV
Max. fuse
Frame size
NH000
Max. rated current, gL/gG
125 A
Max. admissible heat dissipation NH-SE [Pv]
8 W
Terminal capacity
Box terminalStranded
1.5 - 50 mm2
Box terminalCopper strip [Number of segments x width x thickness]
6 x 9 x 0.8 mm
Notes

Fuse-link

Design verification as per IEC/EN 61439

Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+55 °C

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Fuse switch disconnector (EC001040)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Fuse switch disconnector ([email protected] [AKF058013])
Version as main switch
No
Version as safety switch
No
Max. rated operation voltage Ue AC
500 V
Rated permanent current Iu
100 A
Rated operation power at AC-23, 400 V
0 kW
Conditioned rated short-circuit current Iq
50 kA
Rated short-time withstand current lcw
0 kA
Suitable for fuses
NH000
Number of poles
3
With error protection
No
Type of electrical connection of main circuit
Screw connection
Cable entry
Other
Equipped with connectors
No
Suitable for ground mounting
No
Suitable for front mounting 4-hole
No
Suitable for busbar mounting
Yes
Type of control element
Cover grip
Position control element
Front side
Motor drive optional
No
Motor drive integrated
No
Version as emergency stop installation
No
Degree of protection (IP), front side
IP20

Dimensions

1220DIM-38

ETIM for 284690 Low-voltage industrial controls and switchgear (EC001040)
Feature Name Feature Value
Version as main switch (EF006981) No
Version as safety switch (EF006985) No
Max. rated operation voltage Ue AC (EF007355) 500 V
Rated permanent current Iu (EF001389) 100 A
Rated operation power at AC-23, 400 V (EF007027) 0 kW
Conditioned rated short-circuit current Iq (EF001444) 50 kA
Rated short-time withstand current lcw (EF007050) 0 kA
Suitable for fuses (EF006692) NH000
Number of poles (EF001391) 3
With error protection (EF007384) No
Type of electrical connection of main circuit (EF006819) Screw connection
Cable entry (EF000537) Other
Equipped with connectors (EF011696) No
Suitable for floor mounting (EF007243) No
Suitable for front mounting (EF007246) No
Suitable for busbar mounting (EF007259) Yes
Type of control element (EF006976) Cover grip
Position control element (EF009410) Front
Motor drive optional (EF007386) No
Motor drive integrated (EF006697) No
Version as emergency stop installation (EF006959) No
Degree of protection (IP), front side (EF003118) IP20

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.