EATON - MOELLER LPC50 LPC50 1713613 Y8-1713613 EATON ELECTRIC Switch-disconnector fuse, LPC, 50 A, cabinet mount View larger
Images are for illustrative purposes only. Please refer to data sheet for details

LPC50 1713613 Y8-1713613 EATON ELECTRIC Switch-disconnector fuse, LPC, 50 A, cabinet mount

LPC50

1713613

Y8-1713613

EATON - MOELLER

1 Pcs.

Switch-disconnector fuse, LPC, 50 A, cabinet mount Eaton LPC Fuse switch-disconnector, LPC, 50 A, service distribution board mounting, 1 pole, DIII Fuse switch-disconnector 50A, D III, 1 pole, can be switched by neutral conductor, with adapter plate for fuses with 35A, 50 A

Connectors > Fuse switch disconnector
Industrial Fuse Bases

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton LPC Fuse switch-disconnector
Catalog Number
1713613
Model Code
LPC50
EAN
8711426957442
Product Length/Depth
95 mm
Product Height
93 mm
Product Width
40 mm
Product Weight
195.89 g
Certifications
VDE 0660
KEMA
IEC/EN 60204
IEC/EN 60947
CE
IEC/EN 60947-3
RoHS

Features & Functions

Fitted with:
Error protection
Connectors
Number of poles
Two-pole

General

Actuator type
Rocker lever
Degree of protection
IP20
Degree of protection (front side)
IP20
Mounting method
Service distribution board mounting
Mounting position
As required
Overvoltage category
III
Pollution degree
3
Product category
Fuse switch-disconnector

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
50 °C
Ambient storage temperature - min
-30 °C
Ambient storage temperature - max
80 °C
Operating temperature - min
-25 °C
Operating temperature - max
55 °C

Terminal capacities

Terminal capacity (flexible)
1.5 - 10 mm²
Terminal capacity (solid)
1.5 - 16 mm²
Stripping length (main cable)
8 mm
Tightening torque
3 Nm, Screw terminals

Electrical rating

Rated operating voltage (Ue) at AC - max
400 V
Rated operational power at AC-23A, 400 V, 50 Hz
0 kW
Rated short-time withstand current (Icw)
0 kA
Rated uninterrupted current (Iu)
50 A
Uninterrupted current
Rated uninterrupted current Iu is specified for max. cross-section.

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
5 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 1713613 Low-voltage industrial controls and switchgear (EC001040)
Feature Name Feature Value
Version as main switch (EF006981) No
Version as safety switch (EF006985) No
Max. rated operation voltage Ue AC (EF007355) 400 V
Rated permanent current Iu (EF001389) 50 A
Rated operation power at AC-23, 400 V (EF007027) 0 kW
Conditioned rated short-circuit current Iq (EF001444) 0 kA
Rated short-time withstand current lcw (EF007050) 0 kA
Suitable for fuses (EF006692) Other
Number of poles (EF001391) 2
With error protection (EF007384) Yes
Type of electrical connection of main circuit (EF006819) Screw connection
Cable entry (EF000537) Above/under
Equipped with connectors (EF011696) Yes
Suitable for floor mounting (EF007243) No
Suitable for front mounting (EF007246) No
Suitable for busbar mounting (EF007259) No
Type of control element (EF006976) Rocker lever
Position control element (EF009410) Front
Motor drive optional (EF007386) No
Motor drive integrated (EF006697) No
Version as emergency stop installation (EF006959) No
Degree of protection (IP), front side (EF003118) IP20

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.