EATON - MOELLER NH-SLS-00/160 NH-SLS-00/160 106210 EATON ELECTRIC Low-voltage h.b.c fuse switch strip, 160A, 500V/160A, 690V/160A, size 00 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

NH-SLS-00/160 106210 EATON ELECTRIC Low-voltage h.b.c fuse switch strip, 160A, 500V/160A, 690V/160A, size 00

NH-SLS-00/160

106210

EATON - MOELLER

1 Pcs.

Low-voltage h.b.c fuse switch strip, 160A, 500V/160A, 690V/160A, size 00 H.b.c fuse switch strip, rated operational current 160A, max. fuse-link 500V/160A, max. fuse-link 690V/160A, size 00, without safety monitoring

Automation > In-line fuse base

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Low-voltage h.b.c fuse switch strip, 160A, 500V/160A, 690V/160A, size 00
H.b.c fuse switch strip, rated operational current 160A, max. fuse-link 500V/160A, max. fuse-link 690V/160A, size 00, without safety monitoring
[

Delivery program

Product range
185 mm system
Basic function
Busbar fuse material
Subrange
Low-voltage h.b.c. switch-fuse units
Description
100 millimeter between busbar centres, optionally with 185 mm adapters
Without fuse monitoring
With connection area cover
Screw fixing on busbar with drilled holes
Information about equipment supplied
With clamp/screw connection set
Interval between busbar centres
100 mm
Rated operational current [Ie]
160 A
Max. fuse
400 V
160 A
690 V
160 A
Frame size
00
For use with
30 x 10
40 x 10
50 x 10
60 x 10
80 x 10
100 x 10
120 x 10
For use with
Double T profile
Triple T profile
Connection
top or bottom
,

Technical data

General
Standards
IEC/EN 60947-3
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
-5 - +40
Altitude
max. 2000 m m
Interval between busbar centres
100 mm
Number of poles/phases
3 n
Mounting position
Vertical, horizontal
Overvoltage category/pollution degree
III/3
Protection type
IP30 (Operating state)
IP10 (Front cover open)
Degree of Protection
IP30
Direction of incoming supply
as required
Lifespan, mechanical [Operations]
1400
Weight
1.37 kg
Contacts
Rated frequency [f]
50 - 60 Hz
Rated insulation voltage [Ui]
1000 V
Rated operating mode
continuous operation
Rated impulse withstand voltage [Uimp]
8 kV
Interval between busbar centres
100 mm
Overvoltage category/pollution degree
III/3
Rated operational current [Ie]
160 A
690 V
160 A
Rated conditional short-circuit current AC [Iq]
50 kAeff
Utilization category AC­22BRated operating voltage [Ue]
690 V AC
Utilization category AC­22BRated operating current [Ie]
160 A
Utilization category AC-23BRated operating voltage [Ue]
500/400 V AC
Utilization category AC-23BRated operating current [Ie]
125/160 A
Utilization category AC-21BRated operating voltage [Ue]
690 V AC
Utilization category AC-21BRated operating current [Ie]
160 A
Electrical
≧ 200 Operations
Heat dissipation at IthAC, without NH-SE
20 W
Electrical data
Number of poles
3 pole
Number of poles
3
Rated operational voltage [Ue]Rated operating voltage [Ue]
400 V AC
Rated frequency [f]
50 - 60 Hz
Rated operational current [Ie]
160 A
Conventional thermal current [Ith]
160 A
Control mode
Uninterrupted operation
Overvoltage category
III
Rated impulse withstand voltage [Uimp]
8 kV
Power lossFuse
20 W at 160 A W
Relay contacts
Electrical
≧ 200 Operations
Lifespan, mechanical [Operations]
1400
Max. fuse
Frame size
00
Max. rated operational current gL/gG
160 A
Max. admissible heat dissipation NH-SE [Pv]
12 W
Terminal capacity
Box terminalCopper band [Number of segments x width x thickness ]
6 x 9 x 0.8 mm
Flange connectionDiameter [d]
M8 mm
Flange connectionStranded with cable lug
1 x 70 mm2
Flange connectionFlat busbar [max.]
20 x 10 mm
Box terminalStranded
1.5 - 70 mm2
Box terminalFlat conductor [Lamellenzahl x Breite x Dicke ]
6 x 9 x 0.8 mm
Mechanical variables
Mounting on busbarsAdapter for busbars
Z-…SAD
Z-…SADD
Mounting on busbarsScrew connection for busbars
Only in combination with adapter for
M8
… x 5/10
Lifespan, mechanical [Operations]
1400
Overvoltage category/pollution degree
III/3
,

Design verification as per IEC/EN 61439

Operating ambient temperature min.
-5 °C
Operating ambient temperature max.
+40 °C
,

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / In-line fuse base (EC001046)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Fuse strip ([email protected] [AKF059013])
Model
Fuse switch disconnector
Double interrupting
No
Rated permanent current Iu
160 A
Distance between rail centre, 40 mm
No
Distance between rail centre, 50 mm
No
Distance between rail centre, 60 mm
No
Distance between rail centre, 100 mm
Yes
Distance between rail centre, 185 mm
Yes
Max. rated operation voltage Ue AC
690 V
Conditioned rated short-circuit current Iq
50 kA
Type of electrical connection of main circuit
Rail connection
Number of poles
3
Construction size fuse insert
NH00
Release indication
None
,

Dimensions

]

ETIM for 106210 Low-voltage industrial controls and switchgear (EC001046)
Feature Name Feature Value
Model (EF000010) Fuse switch disconnector
Double interrupting (EF007103) No
Rated permanent current Iu (EF001389) 160 A
Distance between rail centre, 40 mm (EF001431) No
Distance between rail centre, 50 mm (EF001430) No
Distance between rail centre, 60 mm (EF001432) No
Distance between rail centre, 100 mm (EF006048) Yes
Distance between rail centre, 185 mm (EF006049) Yes
Max. rated operation voltage Ue AC (EF007355) 690 V
Conditioned rated short-circuit current Iq (EF001444) 50 kA
Type of electrical connection of main circuit (EF006819) Rail connection
Number of poles (EF001391) 3
Construction size fuse insert (EF001452) NH00
Release indication (EF011943) None

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.