EATON - MOELLER PKZM0-XDM12 PKZM0-XDM12 283149 Y7-283149 EATON ELECTRIC Kit, +component adapter, for DOL starter for DILM7-M15 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PKZM0-XDM12 283149 Y7-283149 EATON ELECTRIC Kit, +component adapter, for DOL starter for DILM7-M15

PKZM0-XDM12

283149

Y7-283149

EATON - MOELLER

1 Pcs.

Kit, +component adapter, for DOL starter for DILM7-M15 PKZM0-XDM12 Eaton Moeller® series PKZM0 Wiring set, For DOL Starter, DILM7-M15 Wiring set can be used for DOL starter for PKZM0 + DILM7, PKZM0 + DILM9, PKZM0 + DILM12, PKZM0 + DILM15

Automation > Wiring set for power circuit breaker
Circuit Breakers PKZ

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Moeller® series PKZM0 Accessory Wiring set
Catalog Number
283149
Model Code
PKZM0-XDM12
EAN
4015082831493
Product Length/Depth
91 mm
Product Height
67 mm
Product Width
45 mm
Product Weight
0.058 kg
Certifications
UL
UL File No.: E36332
CSA-C22.2 No. 14
CE
CSA
IEC/EN 60947-4-1
CSA Class No.: 3211-05
CSA File No.: 165628
UL 508
UL Category Control No.: NLRV
Catalog Notes
Cannot be combined with NHI‐E…PKZ0‐PI. Ue ≦ 415 V

General information

Accessories
Cable routing, main current wiring between PKZM0 and contactor with tool-less plug connection, mechanical connection element for PKZM0 and contactor included with supplied equipment.
Model
Direct circuit
Product category
Accessories
Product category
Accessories
Type
Wiring set

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C

Electrical rating

Rated operational current (Ie)
15 A
Rated operational voltage (Ue) - max
415 VAC

Design verification

Equipment heat dissipation, current-dependent Pvid
1.5 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0.5 W
Rated operational current for specified heat dissipation (In)
15.5 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 283149 Low-voltage industrial controls and switchgear (EC002050)
Feature Name Feature Value
Suitable for number of poles (EF001589) 3
Model (EF000010) Direct circuit

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.