View larger
IZMX40N4-P12F-1 183765 Y7-183765 EATON ELECTRIC Circuit-breaker, 4 pole, 1250 A, 85 kA, P measurement, IEC, ..
IZMX40N4-P12F-1
183765
Y7-183765
EATON - MOELLER
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers IZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller circuit-breaker, part number IZMX40N4-P12F-1, provides reliable circuit protection and power measurement capabilities for high-demand electrical networks. These breakers are standard in industrial switchboards for fault interruption.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 1250 A
- Rated voltage (EF003977): 690 V
- Overload release current setting (EF002336): 500 A
- Adjustment range undelayed short-circuit release (EF007131): 2500 A
- Power loss (EF005387): 60 W
- Device construction (EF008240): Built-in device fixed built-in technique
- Integrated earth fault protection (EF007296): No
- Type of electrical connection of main circuit (EF006819): Rail connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): No
- DIN rail (top hat rail) mounting optional (EF008904): No
- With switched-off indicator (EF007006): Yes
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 4
- Position of connection for main current circuit (EF006671): Back
- Type of control element (EF006976): Push button
- Complete device with protection unit (EF008906): Yes
More info
▲General specifications
IEC
RoHS conform
Delivery program
Technical data - electrical
20000 operations (switching cycles ON/OFF, with maintenance)
Technical data - mechanical
IP31
IP31 with door seals
12500 switching cycles (ON/OFF)
Design verification as per IEC/EN 61439 - technical data
Design verification as per IEC/EN 61439
Additional information
Motor drive optional
- External IZMX-DTP-PTM-1 voltage measuring module required (1 module is suitable for 16 circuit breakers)
- suitable for zone selectivity
- suitable for communication
- with integrated system monitor
- with integrated test possibility
- With graphic LCD display
- optionally fittable by user with comprehensive accessories
- Terminal capacity hint: These are values used in separate switchgear. The actual values will depend on the temperature around the circuit breaker, which is influenced by the ambient temperature, the degree of protection (IP), the mounting height, the partitions, and any external ventilation. Depending on the specific switchgear design, this may result in derating, which can then be compensated for by increasing the cross-sectional area. Temperature rise tests in the specific switchgear can provide specific and detailed information.
Air circuit breakers/switch-disconnector