View larger
IZMX40H3-P16W-1 183606 Y7-183606 EATON ELECTRIC Circuit-breaker, 3 pole, 1600 A, 105 kA, P measurement, IEC,..
IZMX40H3-P16W-1
183606
Y7-183606
EATON - MOELLER
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers IZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Circuit-breaker, 3 pole, 1600 A, 105 kA, P measurement, IEC,.. IZMX40H3-P16W-1 from Eaton Moeller is a heavy-duty air circuit breaker engineered to manage and protect high-capacity electrical systems and commercial power distribution grids. Industrial facilities rely on these robust switching devices to safely isolate fault currents and maintain operational continuity. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 1600 A
- Rated voltage (EF003977): 690 V
- Overload release current setting (EF002336): 640 A
- Adjustment range undelayed short-circuit release (EF007131): 3200 A
- Power loss (EF005387): 140 W
- Device construction (EF008240): Built-in device slide-in technique (withdrawable)
- Integrated earth fault protection (EF007296): No
- Type of electrical connection of main circuit (EF006819): Rail connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): No
- DIN rail (top hat rail) mounting optional (EF008904): No
- With switched-off indicator (EF007006): Yes
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Position of connection for main current circuit (EF006671): Back
- Type of control element (EF006976): Push button
- Complete device with protection unit (EF008906): Yes
More info
▲General specifications
IEC/EN 60947
RoHS conform
Delivery program
Technical data - electrical
20000 operations (switching cycles ON/OFF, with maintenance)
Technical data - mechanical
IP55 with protective cover
IP31 with door seals
12500 switching cycles (ON/OFF)
Design verification as per IEC/EN 61439 - technical data
Design verification as per IEC/EN 61439
Additional information
Motor drive optional
- Cassette must be separately ordered.
- External IZMX-DTP-PTM-1 voltage measuring module required (1 module is suitable for 16 circuit breakers)
- IZMX-DTP-PTM external voltage measuring module required
- suitable for zone selectivity
- suitable for communication
- with integrated system monitor
- with integrated test possibility
- With graphic LCD display
- optionally fittable by user with comprehensive accessories
- Terminal capacity hint: These are values used in separate switchgear. The actual values will depend on the temperature around the circuit breaker, which is influenced by the ambient temperature, the degree of protection (IP), the mounting height, the partitions, and any external ventilation. Depending on the specific switchgear design, this may result in derating, which can then be compensated for by increasing the cross-sectional area. Temperature rise tests in the specific switchgear can provide specific and detailed information.
Air circuit breakers/switch-disconnector