View larger
IZMX40H3-P10W-1 183604 Y7-183604 EATON ELECTRIC Circuit-breaker, 3 pole, 1000 A, 105 kA, P measurement, IEC,..
IZMX40H3-P10W-1
183604
Y7-183604
EATON - MOELLER
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers IZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Providing robust fault protection for medium-voltage and industrial main distribution, the IZMX40H3-P10W-1 183604 Y7-183604 EATON ELECTRIC Circuit-breaker, 3 pole, 1000 A, 105 kA, P measurement, IEC,.. operates as a high-performance withdrawable circuit breaker. Electrical engineers specify these three-pole breakers to guarantee selective tripping and reliable power monitoring in complex switchgear setups. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 1000 A
- Rated voltage (EF003977): 690 V
- Overload release current setting (EF002336): 400 A
- Adjustment range undelayed short-circuit release (EF007131): 2000 A
- Power loss (EF005387): 55 W
- Device construction (EF008240): Built-in device slide-in technique (withdrawable)
- Integrated earth fault protection (EF007296): No
- Type of electrical connection of main circuit (EF006819): Rail connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): No
- DIN rail (top hat rail) mounting optional (EF008904): No
- With switched-off indicator (EF007006): Yes
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Position of connection for main current circuit (EF006671): Back
- Type of control element (EF006976): Push button
- Complete device with protection unit (EF008906): Yes
More info
▲General specifications
IEC/EN 60947
RoHS conform
Delivery program
Technical data - electrical
20000 operations (switching cycles ON/OFF, with maintenance)
Technical data - mechanical
IP31
IP31 with door seals
12500 switching cycles (ON/OFF)
Design verification as per IEC/EN 61439 - technical data
Design verification as per IEC/EN 61439
Additional information
Complete device with protection unit
- Cassette must be separately ordered.
- External IZMX-DTP-PTM-1 voltage measuring module required (1 module is suitable for 16 circuit breakers)
- IZMX-DTP-PTM external voltage measuring module required
- suitable for zone selectivity
- suitable for communication
- with integrated system monitor
- with integrated test possibility
- With graphic LCD display
- optionally fittable by user with comprehensive accessories
- Terminal capacity hint: These are values used in separate switchgear. The actual values will depend on the temperature around the circuit breaker, which is influenced by the ambient temperature, the degree of protection (IP), the mounting height, the partitions, and any external ventilation. Depending on the specific switchgear design, this may result in derating, which can then be compensated for by increasing the cross-sectional area. Temperature rise tests in the specific switchgear can provide specific and detailed information.
Air circuit breakers/switch-disconnector