View larger
IZMX16H4-V06W-1 183569 Y7-183569 EATON ELECTRIC Circuit-breaker, 4 pole, 630 A, 66 kA, Selective operation, ..
IZMX16H4-V06W-1
183569
Y7-183569
EATON - MOELLER
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Circuit Breakers IZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller IZMX16H4-V06W-1 circuit-breaker is a withdrawable power switching device designed to safeguard heavy electrical systems from overloads and short circuits. Such breakers are typically integrated into withdrawable switchgear assemblies to facilitate safe maintenance and reliable circuit isolation in industrial plants.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 630 A
- Rated voltage (EF003977): 690 V
- Overload release current setting (EF002336): 252 A
- Adjustment range undelayed short-circuit release (EF007131): 1260 A
- Power loss (EF005387): 50 W
- Device construction (EF008240): Built-in device slide-in technique (withdrawable)
- Integrated earth fault protection (EF007296): No
- Type of electrical connection of main circuit (EF006819): Rail connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): No
- DIN rail (top hat rail) mounting optional (EF008904): No
- With switched-off indicator (EF007006): Yes
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 4
- Position of connection for main current circuit (EF006671): Back
- Type of control element (EF006976): Push button
- Complete device with protection unit (EF008906): Yes
More info
▲General specifications
IEC/EN 60947
RoHS conform
Delivery program
Technical data - electrical
20000 operations (switching cycles ON/OFF, with maintenance)
Technical data - mechanical
IP31
IP31 with door seals
25000 operations (switching capacity, with maintenance)
Design verification as per IEC/EN 61439 - technical data
Design verification as per IEC/EN 61439
Additional information
Complete device with protection unit
- Cassette must be separately ordered.
- Main terminals must be separately ordered.
- suitable for zone selectivity
- optionally fittable by user with comprehensive accessories
- Terminal capacity hint: These are values used in separate switchgear. The actual values will depend on the temperature around the circuit breaker, which is influenced by the ambient temperature, the degree of protection (IP), the mounting height, the partitions, and any external ventilation. Depending on the specific switchgear design, this may result in derating, which can then be compensated for by increasing the cross-sectional area. Temperature rise tests in the specific switchgear can provide specific and detailed information.
Open circuit breaker