Request QuoteProduct Overview
Designed by Eaton Moeller, the IZMX16B3-P12F-1 183359 Y7-183359 EATON ELECTRIC Circuit-breaker, 3 pole, 1250 A, 42 kA, P measurement, IEC, .. is a specialized three-pole circuit breaker. Main distribution boards and industrial switchboards utilize such apparatuses to manage electrical loads and protect sensitive hardware from overcurrent damage. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated permanent current Iu (EF001389): 1250 A
- Rated voltage (EF003977): 690 V
- Overload release current setting (EF002336): 500 A
- Adjustment range undelayed short-circuit release (EF007131): 2500 A
- Power loss (EF005387): 132 W
- Device construction (EF008240): Built-in device fixed built-in technique
- Integrated earth fault protection (EF007296): No
- Type of electrical connection of main circuit (EF006819): Rail connection
- Suitable for DIN rail (top hat rail) mounting (EF007250): No
- DIN rail (top hat rail) mounting optional (EF008904): No
- With switched-off indicator (EF007006): Yes
- With integrated under voltage release (EF001390): No
- Number of poles (EF001391): 3
- Position of connection for main current circuit (EF006671): Back
- Type of control element (EF006976): Push button
- Complete device with protection unit (EF008906): Yes
More info
▲General specifications
IEC
RoHS conform
Delivery program
Technical data - electrical
10000 operations (switching capacity)
Technical data - mechanical
IP31
IP31 with door seals
25000 operations (switching capacity, with maintenance)
Design verification as per IEC/EN 61439 - technical data
Design verification as per IEC/EN 61439
Additional information
Motor drive optional
- External IZMX-DTP-PTM-1 voltage measuring module required (1 module is suitable for 16 circuit breakers)
- suitable for zone selectivity
- suitable for communication
- with integrated system monitor
- with integrated test possibility
- With graphic LCD display
- optionally fittable by user with comprehensive accessories
- Terminal capacity hint: These are values used in separate switchgear. The actual values will depend on the temperature around the circuit breaker, which is influenced by the ambient temperature, the degree of protection (IP), the mounting height, the partitions, and any external ventilation. Depending on the specific switchgear design, this may result in derating, which can then be compensated for by increasing the cross-sectional area. Temperature rise tests in the specific switchgear can provide specific and detailed information.