Rating plug, 1250A, IZMX16, Iu = 1250A
Rate current module for adapting to changes in the basic conditions for an application. The rate current module's nominal value must be less than or equal to the basic device’s rated current. The rate current module can be replaced on site without replacing the transformer. Rate current module 200 A, 250 A and 300 A can be combined with P-trip units.
Automation > Current transformer
Circuit Breakers IZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller IZMX-RP16B-1250 is a rating plug used to set protective trip parameters and current thresholds in compatible industrial circuit breakers.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Through-feed current converter
- Rated primary current (EF007405): 1250 A
- Rated secondary current (EF007471): 0 A
- Rated secondary apparent power (EF007470): 0 VA
- Accuracy class (EF008842): 1
- Calibrated (EF008836): No
- With contact protection (EF008186): Yes
- Opening diameter (EF005153): 0 mm
- Snap mounting (EF007462): No
- With copper rail (EF007380): No
- Number of primary inputs (EF006947): 1
More info
▲EL-Nummer (Norway)
0004357394
Rating plug, 1250A, IZMX16, Iu = 1250A
Rate current module for adapting to changes in the basic conditions for an application. The rate current module's nominal value must be less than or equal to the basic device’s rated current. The rate current module can be replaced on site without replacing the transformer. Rate current module 200 A, 250 A and 300 A can be combined with P-trip units.
Delivery program
Product range
Accessories
Accessories
Options / accessories trip blocks
Accessories
Rating Plug (rate current module)
The rated current can be reduced by changing the rating plug, for example, in order to adapt to changed conditions in the application.
The rating plug’s nominal value must be less than or equal to the basic device’s rated current.
The rating plug can be replaced on site without replacing the transformer.
200 A, 250 A and 300 A rating plugs cannot be combined with P-trip units.
The rating plug’s nominal value must be less than or equal to the basic device’s rated current.
The rating plug can be replaced on site without replacing the transformer.
200 A, 250 A and 300 A rating plugs cannot be combined with P-trip units.
Rated current [In]
1250 A
Suitable for circuit-breaker Iu=
Iu≦ 1250 A
For use with
IZMX16
Design verification as per IEC/EN 61439
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+70 °C
Technical data ETIM 7.0
Low-voltage industrial components (EG000017) / Current transformer (EC002048)
Electric engineering, automation, process control engineering / Signal processing / Transformer / Current transformer ([email protected] [AAB626014])
Model
Through-feed current converter
Primary rated current
1250 A
Secondary rated current
0 A
Secondary rated apparent power
0 VA
Accuracy class
1
Over current limiting factor
Calibrated
No
With shock protection
Yes
Height opening
0 mm
Width opening
0 mm
Opening diameter
0 mm
Snap mounting
No
With copper rail
No
Secondary connection
Number of primary inputs
1