IZMX-CT40-N Current transformer N, external, IZMX40 External measurement transformer for the N conductor protection or for the earth fault monitoring

Automation > Current transformer
Circuit Breakers IZM

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

IZMX-CT40-N by Eaton Moeller is an external current transformer accessory engineered specifically for neutral conductor monitoring in high-capacity circuit breaker setups. Neutral current transformers help track unbalance and ground faults within complex electrical distribution systems.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Calibrated (EF008836): No
  • With contact protection (EF008186): No
  • Snap mounting (EF007462): No
  • With copper rail (EF007380): No

More info

▲
Delivery programme
Product range
Accessories
Accessories
Current sensor for neutral conductor
The external transformer is required for the earth-fault protection and earth-fault alarm functions.
a) For the neutral conductor in the case of 3-pole circuit-breakers
b) For directly measuring the ground fault current at the grounded neutral point in the case of 3-pole and 4-pole circuit-breakers.
Donotplace a jumper (in the wiring between the transformer and the circuit-breaker's terminals) between: a) 15, 16 and 19, 20; b) 17, 18 and 19, 20.
For use with
IZMX-DTV-G
+IZMX-DTV-G
+IZMX-DTV-GZ
+IZMX-DTU-A
IZMX-DTU-A
+IZMX-DTU-AZ
+IZMX-DTU-G
IZMX-DTU-G
+IZMX-DTU-AM
IZMX-DTU-AM
+IZMX-DTU-AMZ
IZMX-DTU-GMZ
IZMX-DTU-GM
+IZMX-DTU-GM
+IZMX-DTU-GZ
IZMX-DTP-G
IZMX-DTP-G
+IZMX-DTP-GZ
+IZMX-DTP-GM
+IZMX-DTP-GMZ
IZMX-DTP-GM
Notes

An additional control circuit terminal block is required.

For fixed mounting circuit-breakers→#156593 and withdrawable unit circuit-breakers →#156590

Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
Operating ambient temperature min.
°C -25
Operating ambient temperature max.
°C 70
Technical data ETIM 6.0
Low-voltage industrial components (EG000017) / Current transformer (EC002048)
Electric engineering, automation, process control engineering / Signal processing / Transformer / Current transformer ([email protected] [AAB626011])
Model
Wound primary current converter
Primary rated current
A 4000
Secondary rated current
A 0
Secondary rated apparent power
VA 0
Accuracy class
1
Over voltage limiting factor
-
Calibrated
No
With shock protection
No
Opening height
mm 0
Opening width
mm 0
Opening diameter
mm 0
Snap mounting
No
With copper rail
No
Secondary connection
Screw connection
Number of primary inputs
1