EATON - MOELLER IZMX-CT40-N IZMX-CT40-N 156660 EATON ELECTRIC IZMX-CT40-N Current transformer N, external, IZMX40 View larger
Images are for illustrative purposes only. Please refer to data sheet for details

IZMX-CT40-N 156660 EATON ELECTRIC IZMX-CT40-N Current transformer N, external, IZMX40

IZMX-CT40-N

156660

EATON - MOELLER

1 Pcs.

IZMX-CT40-N Current transformer N, external, IZMX40 External measurement transformer for the N conductor protection or for the earth fault monitoring

Automation > Current transformer
Circuit Breakers IZM

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Delivery programme
Product range
Accessories
Accessories
Current sensor for neutral conductor
The external transformer is required for the earth-fault protection and earth-fault alarm functions.
a) For the neutral conductor in the case of 3-pole circuit-breakers
b) For directly measuring the ground fault current at the grounded neutral point in the case of 3-pole and 4-pole circuit-breakers.
Donotplace a jumper (in the wiring between the transformer and the circuit-breaker's terminals) between: a) 15, 16 and 19, 20; b) 17, 18 and 19, 20.
For use with
IZMX-DTV-G
+IZMX-DTV-G
+IZMX-DTV-GZ
+IZMX-DTU-A
IZMX-DTU-A
+IZMX-DTU-AZ
+IZMX-DTU-G
IZMX-DTU-G
+IZMX-DTU-AM
IZMX-DTU-AM
+IZMX-DTU-AMZ
IZMX-DTU-GMZ
IZMX-DTU-GM
+IZMX-DTU-GM
+IZMX-DTU-GZ
IZMX-DTP-G
IZMX-DTP-G
+IZMX-DTP-GZ
+IZMX-DTP-GM
+IZMX-DTP-GMZ
IZMX-DTP-GM
Notes

An additional control circuit terminal block is required.

For fixed mounting circuit-breakers→#156593 and withdrawable unit circuit-breakers →#156590

Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
Operating ambient temperature min.
°C -25
Operating ambient temperature max.
°C 70
Technical data ETIM 6.0
Low-voltage industrial components (EG000017) / Current transformer (EC002048)
Electric engineering, automation, process control engineering / Signal processing / Transformer / Current transformer ([email protected] [AAB626011])
Model
Wound primary current converter
Primary rated current
A 4000
Secondary rated current
A 0
Secondary rated apparent power
VA 0
Accuracy class
1
Over voltage limiting factor
-
Calibrated
No
With shock protection
No
Opening height
mm 0
Opening width
mm 0
Opening diameter
mm 0
Snap mounting
No
With copper rail
No
Secondary connection
Screw connection
Number of primary inputs
1

ETIM for 156660 Low-voltage industrial controls and switchgear (EC002048)
Feature Name Feature Value
Calibrated (EF008836) No
With contact protection (EF008186) No
Snap mounting (EF007462) No
With copper rail (EF007380) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.