View larger
INX40N4-32F-1 184086 Y7-184086 EATON ELECTRIC Switch-disconnector, 4 pole, 3200 A, without protection, IEC, ..
INX40N4-32F-1
184086
Y7-184086
EATON - MOELLER
1 Pcs.
Connectors > Switch disconnector
Circuit Breakers IZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller INX40N4-32F-1 switch-disconnector acts as a high-capacity current interruption device for heavy industrial power distribution networks. Heavy manufacturing plants and large electrical infrastructures rely on such robust switch-disconnectors to manage massive load currents safely during servicing. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Version as main switch (EF006981): Yes
- Version as maintenance-/service switch (EF006986): Yes
- Version as safety switch (EF006985): No
- Version as emergency stop installation (EF006959): No
- Version as reversing switch (EF009408): No
- Number of switches (EF005586): 1
- Max. rated operation voltage Ue AC (EF007355): 690 V
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 3200 A
- Rated permanent current at AC-23, 400 V (EF011777): 3200 A
- Rated permanent current at AC-21, 400 V (EF009165): 0 A
- Rated operation power at AC-3, 400 V (EF001364): 0 kW
- Rated short-time withstand current lcw (EF007050): 85 kA
- Rated operation power at AC-23, 400 V (EF007027): 0 kW
- Switching power at 400 V (EF009166): 0 kW
- Conditioned rated short-circuit current Iq (EF001444): 187 kA
More info
▲General specifications
IEC/EN 60947
RoHS conform
Delivery program
Technical data - electrical
10000 operations (switching cycles ON/OFF, with maintenance)
Technical data - mechanical
IP55 with protective cover
20000 operations (switching capacity, with maintenance)
Design verification as per IEC/EN 61439 - technical data
Design verification as per IEC/EN 61439
Additional information
Version as main switch
Version as maintenance-/service switch
Voltage release optional
- Optionally fittable by user with comprehensive accessories
- Terminal capacity hint: These are values used in separate switchgear. The actual values will depend on the temperature around the circuit breaker, which is influenced by the ambient temperature, the degree of protection (IP), the mounting height, the partitions, and any external ventilation. Depending on the specific switchgear design, this may result in derating, which can then be compensated for by increasing the cross-sectional area. Temperature rise tests in the specific switchgear can provide specific and detailed information.
Ground mounting
Intermediate mounting
Open switch-disconnector