INX40N3-32W-1 184070 Y7-184070 EATON ELECTRIC Switch-disconnector, 3 pole, 3200 A, without protection, IEC, ..
INX40N3-32W-1
184070
Y7-184070
EATON - MOELLER
1 Pcs.
Connectors > Switch disconnector
Circuit Breakers IZM
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller INX40N3-32W-1 functions as a high-capacity switch-disconnector engineered to manage extensive electrical loads without built-in overcurrent trip units in heavy industrial switchgear. Heavy-duty disconnectors safely isolate massive power feeds across major manufacturing facilities and electrical grids.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Version as main switch (EF006981): Yes
- Version as maintenance-/service switch (EF006986): Yes
- Version as safety switch (EF006985): No
- Version as emergency stop installation (EF006959): No
- Version as reversing switch (EF009408): No
- Number of switches (EF005586): 1
- Max. rated operation voltage Ue AC (EF007355): 690 V
- Rated operating voltage (EF001435): 690 V
- Rated permanent current Iu (EF001389): 3200 A
- Rated permanent current at AC-23, 400 V (EF011777): 3200 A
- Rated permanent current at AC-21, 400 V (EF009165): 0 A
- Rated operation power at AC-3, 400 V (EF001364): 0 kW
- Rated short-time withstand current lcw (EF007050): 85 kA
- Rated operation power at AC-23, 400 V (EF007027): 0 kW
- Switching power at 400 V (EF009166): 0 kW
- Conditioned rated short-circuit current Iq (EF001444): 187 kA
More info
▲General specifications
IEC
RoHS conform
Delivery program
Technical data - electrical
5000 operations (switching capacity)
Technical data - mechanical
IP31 with door seals
10000 switching cycles (ON/OFF)
Design verification as per IEC/EN 61439 - technical data
Design verification as per IEC/EN 61439
Additional information
Version as main switch
Version as maintenance-/service switch
Interlockable
- Cassette must be separately ordered.
- Optionally fittable by user with comprehensive accessories
- Terminal capacity hint: These are values used in separate switchgear. The actual values will depend on the temperature around the circuit breaker, which is influenced by the ambient temperature, the degree of protection (IP), the mounting height, the partitions, and any external ventilation. Depending on the specific switchgear design, this may result in derating, which can then be compensated for by increasing the cross-sectional area. Temperature rise tests in the specific switchgear can provide specific and detailed information.
Intermediate mounting
Distribution board installation
Open switch-disconnector