View larger
CI-K2-PKZ0 219653 Y7-219653 EATON ELECTRIC Insulated enclosure, for PKZ0, +cut-out 45mm, IP40 x
CI-K2-PKZ0
219653
Y7-219653
EATON - MOELLER
1 Pcs.
Automation > Empty enclosure for switchgear
Circuit Breakers PKZ
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller® series CI-K Accessory Insulated enclosure, model CI-K2-PKZ0 from Eaton Moeller, provides a dependable mounting shell for motor-protective circuit breakers and auxiliary modules. These protective enclosures keep electrical equipment shielded from airborne particulate matter and accidental contact while facilitating straightforward panel or wall installation. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Product Name: Eaton Moeller® series CI-K Accessory Insulated enclosure
- Catalog Number: 219653
- Model Code: CI-K2-PKZ0
- EAN: 4015082196530
- Product Length/Depth: 105 mm
- Product Height: 180 mm
- Product Width: 100 mm
- Product Weight: 0.33 kg
- Certifications: CE
- Used with: PKZ0 +L-PKZ0 (2 units), +NHI or AGM, +U or A, PKZM0-…
- 10.2.2 Corrosion resistance: Meets the product standard's requirements.
- 10.2.3.1 Verification of thermal stability of enclosures: Meets the product standard's requirements.
- 10.2.4 Resistance to ultra-violet (UV) radiation: Please enquire
- 10.2.5 Lifting: Does not apply, since the entire switchgear needs to be evaluated.
- 10.2.6 Mechanical impact: Does not apply, since the entire switchgear needs to be evaluated.
- 10.2.7 Inscriptions: Meets the product standard's requirements.
More info
▲General specifications
| Product Name | Eaton Moeller® series CI-K Accessory Insulated enclosure |
| Catalog Number | 219653 |
| Model Code | CI-K2-PKZ0 |
| EAN | 4015082196530 |
| Product Length/Depth | 105 mm |
| Product Height | 180 mm |
| Product Width | 100 mm |
| Product Weight | 0.33 kg |
| Certifications | CE |
| Catalog Notes | Additional cable insertion membrane as cable entry gland: 2 x in the rear wall and 1 x at the bottom. |
Product specifications
| Used with | PKZ0 +L-PKZ0 (2 units), +NHI or AGM, +U or A, PKZM0-… |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Please enquire |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Fitted with: | N and PE terminal Cover with aperture dimensioned to accommodate front of breaker |
| Enclosure material | Plastic |
| Ambient operating temperature - max | 70 °C |
| Ambient operating temperature - min | -25 °C |
| Equipment heat dissipation, current-dependent Pvid | 0 W |
| Heat dissipation capacity Pdiss | 10 W |
| Heat dissipation per pole, current-dependent Pvid | 0 W |
| Rated operational current for specified heat dissipation (In) | 0 A |
| Static heat dissipation, non-current-dependent Pvs | 0 W |
| Product category | Accessories |
| Degree of protection | IP41, when mounted vertically IP40 NEMA Other |
| Model | Surface mounting |
| Degree of protection (front side) | IP40 |
| Knockouts | 2 x M25 (cable entry knockout at the top) 2 x M25 (cable entry knockout at the bottom) |