The Eaton Moeller M22-L-B indicator light functions as a visual signaling device deployed across industrial control panels to communicate operational states and system alerts. Maintenance and control personnel rely on these units to monitor complex machinery workflows. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Name: Eaton Moeller® series M22 Indicator light
- Catalog Number: 216775
- Model Code: M22-L-B
- EAN: 4015082167752
- Product Length/Depth: 30 mm
- Product Height: 30 mm
- Product Width: 30 mm
- Product Weight: 0.007 kg
- Bezel color: Chrome
- Design: Flush
- Fitted with:: Front ring
- Lens color: Blue
- Degree of protection: NEMA 4X, 13
- Degree of protection (front side): IP67/IP69K
- Opening diameter: 22.5 mm
- Overvoltage category: III
More info
▲General specifications
| Product Name | Eaton Moeller® series M22 Indicator light |
| Catalog Number | 216775 |
| Model Code | M22-L-B |
| EAN | 4015082167752 |
| Product Length/Depth | 30 mm |
| Product Height | 30 mm |
| Product Width | 30 mm |
| Product Weight | 0.007 kg |
| Certifications | CE CSA-C22.2 No. 14-05 UL File No.: E29184 CSA Class No.: 3211-03 CSA-C22.2 No. 94-91 CSA IEC/EN 60947 VDE 0660 UL UL Category Control No.: NKCR CSA File No.: 012528 IEC/EN 60947-5 UL 508 |
Features & Functions
| Bezel color | Chrome |
| Bezel material | Other |
| Design | Flush |
| Fitted with: | Front ring |
| Lens color | Blue |
General information
| Degree of protection | NEMA 4X, 13 |
| Degree of protection (front side) | IP67/IP69K |
| Opening diameter | 22.5 mm |
| Overvoltage category | III |
| Pollution degree | 3 |
| Product category | RMQ-Titan |
| Product category | RMQ-Titan |
| Rated impulse withstand voltage (Uimp) | 4000 V AC |
| Size | Front diameter: 29.7 mm |
| Type | Indicator lights |
Ambient conditions, mechanical
| Mounting position | As required |
| Shock resistance | Mechanical, According to IEC/EN 60068-2-27 30 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms |
Climatic environmental conditions
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature - max | 70 °C |
| Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Terminal capacities
| Terminal capacity | 0.5 - 1.5 mm², solid 0.5 - 1.5 mm², stranded |
Electrical rating
| Rated insulation voltage (Ui) | 250 V |
Communication
| Connection to SmartWire-DT | Yes With SWD-RMQ connections |
Contacts
| Force for positive opening - min | 0 N |
Design verification
| Equipment heat dissipation, current-dependent Pvid | 0 W |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 0 W |
| Rated operational current for specified heat dissipation (In) | 0 A |
| Static heat dissipation, non-current-dependent Pvs | 0 W |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Please enquire |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | Not applicable. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |